z-logo
open-access-imgOpen Access
Magnetic Bead Based Immunoassay for Autonomous Detection of Toxins
Author(s) -
Youngeun Kwon,
Christine A. Hara,
Mark G. Knize,
Mona H. Hwang,
Kodumudi S. Venkateswaran,
Elizabeth K. Wheeler,
P. M. Bell,
Ronald F. Renzi,
Julie A. Fruetel,
Christopher G. Bailey
Publication year - 2008
Publication title -
analytical chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.117
H-Index - 332
eISSN - 1520-6882
pISSN - 0003-2700
DOI - 10.1021/ac8010044
Subject(s) - chemistry , capillary electrophoresis , immunoassay , chromatography , streptavidin , detection limit , toxoid , fluorescence , multiplex , primary and secondary antibodies , antigen , biotin , antibody , biochemistry , bioinformatics , genetics , physics , immunization , quantum mechanics , immunology , biology
We are developing an automated system for the simultaneous, rapid detection of a group of select agents and toxins in the environment. To detect toxins, we modified and automated an antibody-based approach previously developed for manual medical diagnostics that uses fluorescent eTag reporter molecules and is suitable for highly multiplexed assays. Detection is based on two antibodies binding simultaneously to a single antigen, one of which is labeled with biotin while the other is conjugated to a fluorescent eTag through a cleavable linkage. Aqueous samples are incubated with the mixture of antibodies along with streptavidin-coated magnetic beads and a photoactive porphyrin complex. In the presence of antigen, a molecular complex is formed where the cleavable linkage is held in proximity to the photoactive group. Upon excitation at 680 nm, free radicals are generated, which diffuse and cleave the linkage, releasing the eTags. Released eTags are analyzed using capillary gel electrophoresis with laser-induced fluorescence detection. Limits of detection for ovalbumin and botulinum toxoid individually were 4 (or 80 pg) and 16 ng/mL (or 320 pg), respectively, using the manual assay. In addition, we demonstrated the use of pairs of antibodies from different sources in a single assay to decrease the rate of false positives. Automation of the assay was demonstrated in a flow-through format with higher LODs of 32 ng/mL (or 640 ng) each of a mixture of ovalbumin and botulinum toxoid. This versatile assay can be easily modified with the appropriate antibodies to detect a wide range of toxins and other proteins.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom