z-logo
open-access-imgOpen Access
Impact of DG different types on the grid performance
Author(s) -
Ahmed Abd-Rabou,
A.M. Soliman,
Ahmad Safawi Mokhtar
Publication year - 2015
Publication title -
journal of electrical systems and information technology
Language(s) - English
Resource type - Journals
ISSN - 2314-7172
DOI - 10.1016/j.jesit.2015.04.001
Subject(s) - particle swarm optimization , voltage sag , photovoltaic system , matlab , grid , voltage , distributed generation , computer science , electric power system , voltage drop , power (physics) , engineering , control theory (sociology) , electronic engineering , renewable energy , electrical engineering , power quality , mathematics , algorithm , physics , geometry , control (management) , quantum mechanics , artificial intelligence , operating system
Distributed generation (DG) is playing an important role in power system to improve the grid performance. Optimizing the locations of DGs is necessary to enhance the Grid performance and to avoid the degradation of the power system networks. The type of DG directly influences the penetration level and the placement of DG. In this study, genetic algorithm (GA) technique is proposed to find the optimum location for three different types of distributed generation, these types are synchronous generator, wind turbine and photovoltaic. The obtained results are also validated using Particle Swarm Optimization (PSO). Three different types of DGs will be penetrated individually to find their optimum location and investigate their impact on the grid performance. This approach will be applied on IEEE 13 bus system which is simulated using Power System Computer Aided Design (PSCAD) and Matlab software. GA and PSO are used to find the optimum solution of multi-objective function; the objective function combines the overall number of buses experience voltage sag, the number of buses experience voltage drop, the number of buses experience voltage less than 10%, the overall number of buses experience voltage swell and network power loss. Finally, results are analyzed, discussed and validated which show that the optimum locations of each DG will vary according to the type of DG but all of them will be around the load center. In the mean time, results showed that the highest grid overall performance was for synchronous generator DG and the lowest for photovoltaic DG

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here