Myocardial Perfusion Imaging With Contrast Ultrasound
Author(s) -
Thomas R. Porter,
Feng Xie
Publication year - 2010
Publication title -
jacc. cardiovascular imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 5.79
H-Index - 120
eISSN - 1936-878X
pISSN - 1876-7591
DOI - 10.1016/j.jcmg.2009.09.024
Subject(s) - microbubbles , perfusion , medicine , perfusion scanning , ultrasound , microcirculation , myocardial perfusion imaging , radiology , contrast (vision) , cardiology , computer science , artificial intelligence
This report reviews the development and clinical application of myocardial perfusion imaging with myocardial contrast echocardiography (MCE). This includes the development of microbubble formulations that permit the detection of left ventricular contrast from venous injection and the imaging techniques that have been invented to detect the transit of these microbubbles through the microcirculation. The methods used to quantify myocardial perfusion during a continuous infusion of microbubbles are described. A review of the clinical studies that have examined the clinical utility of myocardial perfusion imaging with MCE during rest and stress echocardiography is then presented. The limitations of MCE are also discussed.