Treatment of Acute Intravascular Thrombi With Diagnostic Ultrasound and Intravenous Microbubbles
Author(s) -
Feng Xie,
John Lof,
E. Carr Everbach,
Anming He,
Richard Bennett,
Terry O. Matsunaga,
Jason M. Johanning,
Thomas R. Porter
Publication year - 2009
Publication title -
jacc. cardiovascular imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 5.79
H-Index - 120
eISSN - 1936-878X
pISSN - 1876-7591
DOI - 10.1016/j.jcmg.2009.02.002
Subject(s) - microbubbles , intravascular ultrasound , mechanical index , medicine , ultrasound , radiology , nuclear medicine , biomedical engineering
The purpose of this study was to determine whether high mechanical index (MI) impulses from diagnostic ultrasound (DUS) could dissolve intravascular thrombi using intravenous microbubbles. Using a canine model, DUS was applied during a continuous intravenous infusion of microbubbles. Completely thrombosed grafts were assigned to 2 treatment regimens: low-MI (<0.5-MI) ultrasound alone; or intermittent high-MI impulses (1.9-MI) guided by low-MI ultrasound (contrast pulse sequencing). A 20-MHz cavitation detector was placed confocal to the ultrasound transducer to make intravascular cavitation measurements in 1 dog. Intravascular cavitational activity was detected when an MI of >0.5 was applied. In grafts treated with intermittent high-MI ultrasound, angiographic success was 71% at 30 min and 79% at 45 min, compared with 20% and 30% at these times in the low-MI ultrasound alone group (p < 0.05). We conclude that a commercially available DUS transducer can successfully recanalize acute intravascular thrombi during a continuous microbubble infusion.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom