Validation and implementation of the Panbio COVID-19 Ag rapid test for the diagnosis of SARS-CoV-2 infection in symptomatic hospital healthcare workers
Author(s) -
Eva Kolwijck,
M. Brouwers-Boers,
Jorrit Broertjes,
K. van Heeswijk,
N. Runderkamp,
Adam Meijer,
M. H. A. Hermans,
Alexander C. A. P. Leenders
Publication year - 2021
Publication title -
infection prevention in practice
Language(s) - English
Resource type - Journals
ISSN - 2590-0889
DOI - 10.1016/j.infpip.2021.100142
Subject(s) - covid-19 , medicine , healthcare worker , test (biology) , pcr test , virology , emergency medicine , health care , polymerase chain reaction , biology , disease , gene , infectious disease (medical specialty) , economic growth , biochemistry , economics , outbreak , paleontology
BackgroundRT-PCR is the current recommended laboratory method to diagnose SARS-CoV-2 in healthcare workers (HCW). As RT-PCR is not widely available and is time-consuming, it limits decision making on removal from and return to work of possibly contagious HCW.AimIn this study we evaluated the Panbio™ COVID-19 Ag rapid test (PanbioCAgRT) in 825 hospital HCW.Methodsand findings: This study consisted of two phases. In the validation phase, we tested hospital HCW with mild symptoms (three days or less) in parallel using the PanbioCAgRT and the RT-qPCR test. The PanbioCAgRT demonstrated 86.7% sensitivity, 100% specificity, 100% PPV and 98.5% NPV with regard to RT-qPCR. For HCW with PanbioCAgRT-/RT-qPCR+, the median Ct value was 30.9, whereas for the HCW with PanbioCAgRT+/RT-qPCR+ the median Ct value was 19.3 (p<0.001). In the second phase, we implemented an on-site antigen test-based strategy for symptomatic hospital HCW: HCW that tested positive with the PanbioCAgRT on-site were considered SARS-CoV-2 positive and were sent home. HCW that tested negative with the PanbioCAgRT on-site were allowed to work with PPE pending RT-qPCR test results from the laboratory. Sensitivity of the antigen test-based strategy was 72.5% and NPV was 97%. For HCW with PanbioCAgRT-/RT-qPCR+ median Ct values were 27.8.ConclusionThe PanbioCAgRTt validated in this study showed a high sensitivity and specificity in samples obtained from HCW with high viral loads. The antigen-based testing strategy proposed in this study seems to be effective, safe and easy to implement in a wide range of occupational healthcare settings.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom