Chemotherapy readiness in pediatric oncology: Assessing an automated method to measure urine specific gravity
Author(s) -
Ali H. Algiraigri,
Tony H. Truong,
Martha E. Lyon
Publication year - 2020
Publication title -
hematology/oncology and stem cell therapy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.666
H-Index - 22
eISSN - 1658-3876
pISSN - 2589-0646
DOI - 10.1016/j.hemonc.2020.04.008
Subject(s) - urine , dipstick , urine specific gravity , chemotherapy , medicine , refractometer , gold standard (test) , urology , materials science , optoelectronics , refractive index
As part of the evaluation for chemotherapy readiness, urine specific gravity is measured to assess the patient's overall hydration status. Depending on the accuracy of the methods used, patients may be adversely affected by having their chemotherapy delayed or prematurely started. To evaluate the diagnostic accuracy of a new automated urine dipstick readout device (Clinitek), we tested 196 consecutive urine samples for urine specific gravity and compared them with the practical gold standard, a urine refractometer. We found a high correlation between both tools among clean urine samples, but a poor correlation among the pathological urine samples.