More sensitivity is always better: Measuring sub-clinical levels of serum thyroglobulin on a µLC–MS/MS system
Author(s) -
Christopher M. Shuford,
Jay Johnson,
J. Will Thompson,
Patricia L. Holland,
Andrew N. Hoofnagle,
Russell P. Grant
Publication year - 2020
Publication title -
clinical mass spectrometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.473
H-Index - 8
eISSN - 2376-9998
pISSN - 2213-8005
DOI - 10.1016/j.clinms.2020.01.001
Subject(s) - sensitivity (control systems) , thyroglobulin , chemistry , chromatography , medicine , thyroid , engineering , electronic engineering
Although liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays for thyroglobulin (Tg) are resistant to autoantibody (TgAb) interference, recent studies have demonstrated approximately 40% of TgAb-positive individuals with recurrent thyroid cancer have Tg concentrations below the lower limit of quantification (LLOQ) of the LC-MS/MS assays described to date (i.e., <0.5 ng/mL), resulting in false-negative findings during post-thyroidectomy monitoring. To reduce false negative results due to insufficient analytical sensitivity, a new Tg assay was developed on a commercially available LC-MS/MS system operating at microliter/minute flow-rates (i.e., µLC-MS/MS) to maximize the analytical sensitivity and achieve a LLOQ of 0.02 ng/mL. When applied to the measurement of TgAb-negative and TgAb-positive patient serum samples previously measuring below the LLOQ of current immunometric and LC-MS/MS assays (LLOQ, 0.1-0.2 ng/mL), concentrations were measurable by µLC-MS/MS in 66% and 44% of samples, respectively - possibly explaining the persistence of TgAb in those patients. Patients with low Tg concentrations measured by µLC-MS/MS (<0.1 ng/mL) also exhibited elevation in their Tg concentrations upon hormone stimulation, indicating the detected Tg was produced from remnant thyroid tissue and would be suitable as a tissue biomarker. Forty-eight TgAb-positive patient specimens with undetectable Tg by both conventional LC-MS/MS (<0.15 ng/mL) and immunometric (<0.1 ng/mL) assays demonstrated measureable Tg concentrations by the new µLC-MS/MS assay in approximately one-third of the specimens, despite all patients being disease free at the time of collection, suggesting interference-free monitoring of low Tg levels may be feasible prior to the on-set of recurrent disease using a sensitive LC-MS/MS assay.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom