Comparison of Different Invasive Hemodynamic Measurements as a Prediction Tool for Mortality after Transcatheter Aortic Valve Replacement in Men: A Retrospective Observational Study
Author(s) -
Anthony A. Bavry,
Seyed Hossein AalaeiAndabili,
Ashkan Karimi,
Ki Park,
Calvin Choi,
Eddie W. Manning,
Thomas M. Beaver,
Wade W. Stinson
Publication year - 2017
Publication title -
cardiology and therapy
Language(s) - English
Resource type - Journals
eISSN - 2193-8261
pISSN - 2193-6544
DOI - 10.1007/s40119-017-0095-5
Subject(s) - medicine , cardiology , pulse pressure , hemodynamics , hazard ratio , diastole , blood pressure , heart rate , aortic valve , confidence interval
Hemodynamic measurements can assess for paravalvular aortic regurgitation after transcatheter aortic valve replacement (TAVR). This study compared the utility of different invasive hemodynamic measures in providing prognostic information.