z-logo
Premium
Rapid evaluation of olive oil quality by NIR reflectance spectroscopy
Author(s) -
Mailer Rodney J.
Publication year - 2004
Publication title -
journal of the american oil chemists' society
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.512
H-Index - 117
eISSN - 1558-9331
pISSN - 0003-021X
DOI - 10.1007/s11746-004-0986-4
Subject(s) - olive oil , oleic acid , stearic acid , chemistry , polyphenol , reproducibility , chromatography , food science , environmental science , biochemistry , organic chemistry , antioxidant
NIR spectroscopy calibrations have been developed for a range of quality parameters in olive oil, including FFA, PV, polyphenol content, induction time, chlorophyll, and the major FA. A set of 216 olive oil samples from throughout the Australian olive‐growing areas were used to provide a representative range of quality. The variation in the oils tested virtually covered the range of the chemical standard limits described by the International Olive Oil Council. A FOSS NIRSystems ® 6500 spectrophotometer with a liquid cell holder was used. Multiple correlation coefficients squared ( R 2 ) for minor components stearic acid (0.86), and linolenic acid (0.85) were relatively low because the concentration range is very narrow compared with the reproducibility of the reference method. However, the major FA, oleic (0.99) and linoleic (1.00), FFA (0.97), and chlorophyll (0.98) provided high levels of accuracy. All of the parameters measured were sufficiently accurate for routine screening of olive oil.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here