Cationic surfactant‐selective potentiometric sensors based on neutral ion‐pair carrier complexes
Author(s) -
Mahajan Rakesh Kumar,
Kaur Inderpreet,
Bakshi Mandeep Singh
Publication year - 2004
Publication title -
journal of surfactants and detergents
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.349
H-Index - 48
eISSN - 1558-9293
pISSN - 1097-3958
DOI - 10.1007/s11743-004-0295-9
Subject(s) - chemistry , cationic polymerization , potentiometric titration , pulmonary surfactant , sodium dodecyl sulfate , monomer , inorganic chemistry , vinyl chloride , membrane , ion selective electrode , sodium , micelle , critical micelle concentration , ion , organic chemistry , aqueous solution , selectivity , polymer , biochemistry , copolymer , catalysis
Poly(vinyl chloride) (PVC) membrane electrodes to determine monomer concentrations of tetradecyltrimethylammonium ion (TTA + ) and hexadecylpyridinium ion (HPy + ) based on neutral ion‐pair carrier complexes of tetradecyltrimethylammonium dodecyl sulfate (TTA + ‐DS − ) and hexadecylpyridinium dodecyl sulfate (HPy + ‐DS − ), respectively, are reported here. The electrodes exhibit a Nernstian slope of 59 mV per decade for TTA + and a sub‐Nernstian slope of 34.5 mV per decade for HPy + ions. The TTA + ion‐selective electrode (ISE) and the HPy + ‐ISE can determine the monomer units down to concentrations as low as 4.0×10 −4 M and 1.66×10 −5 M, respectively. The effect of various additives, such as the anionic polyelectrolyte sodium dextran sulfate and macrocyclic β‐cyclodextrin, on the surface activity exhibited by the cationic surfactants TTA + ‐DS − and HPy + ‐DS − , in the presence of background concentrations of NaCl was also examined with surfactant‐selective sensors. The Gibbs free energy of micelle formation (Δ G m ) of both surfactants in the presence of various additives was calculated and found to be less favorable with respect to an increase in the amount of additives due to less availability of cationic surfactant monomer units. The ion‐pair complexes TTA + ‐DS − and HPy + ‐DS − were found to behave as selective carrier compounds in PVC membranes in determining the concentration of monomer units of both TTA + and HPy + , respectively. The proposed sensors worked well at a fairly acidic pH of 1–6.5 with response time of 60 s. The sensors responded well to the surfactant ions even in the presence of additives at lower concentration. The lifetime of the sensors is 3 mon.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here