Accelerated Estimation of Pulmonary Artery Stenosis Pressure Gradients with Distributed Lumped Parameter Modeling vs. 3D CFD with Instantaneous Adaptive Mesh Refinement: Experimental Validation in Swine
Author(s) -
Ryan Pewowaruk,
Luke Lamers,
Alejandro RoldánAlzate
Publication year - 2021
Publication title -
annals of biomedical engineering
Language(s) - English
Resource type - Journals
eISSN - 1573-9686
pISSN - 0090-6964
DOI - 10.1007/s10439-021-02780-5
Subject(s) - computational fluid dynamics , stenosis , mechanics , pressure gradient , mesh generation , biomedical engineering , cardiology , medicine , physics , finite element method , thermodynamics
Branch pulmonary artery stenosis (PAS) commonly occurs in congenital heart disease and the pressure gradient over a stenotic PA lesion is an important marker for re-intervention. Image based computational fluid dynamics (CFD) has shown promise for non-invasively estimating pressure gradients but one limitation of CFD is long simulation times. The goal of this study was to compare accelerated predictions of PAS pressure gradients from 3D CFD with instantaneous adaptive mesh refinement (AMR) versus a recently developed 0D distributed lumped parameter CFD model. Predictions were then experimentally validated using a swine PAS model (n = 13). 3D CFD simulations with AMR improved efficiency by 5 times compared to fixed grid CFD simulations. 0D simulations further improved efficiency by 6 times compared to the 3D simulations with AMR. Both 0D and 3D simulations underestimated the pressure gradients measured by catheterization (- 1.87 ± 4.20 and - 1.78 ± 3.70 mmHg respectively). This was partially due to simulations neglecting the effects of a catheter in the stenosis. There was good agreement between 0D and 3D simulations (ICC 0.88 [0.66-0.96]) but only moderate agreement between simulations and experimental measurements (0D ICC 0.60 [0.11-0.86] and 3D ICC 0.66 [0.21-0.88]). Uncertainty assessment indicates that this was likely due to limited medical imaging resolution causing uncertainty in the segmented stenosis diameter in addition to uncertainty in the outlet resistances. This study showed that 0D lumped parameter models and 3D CFD with instantaneous AMR both improve the efficiency of hemodynamic modeling, but uncertainty from medical imaging resolution will limit the accuracy of pressure gradient estimations.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here