z-logo
open-access-imgOpen Access
Evaluation of viscoelastic properties, hardness, and glass transition temperature of soft denture liners and tissue conditioner
Author(s) -
Yukiro Kitagawa,
Kazuhiro Yoshida,
Kazuma Takase,
Alireza Valanezhad,
Ikuya Watanabe,
Ken Kojio,
Hiroshi Murata
Publication year - 2019
Publication title -
odontology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.705
H-Index - 33
eISSN - 1618-1255
pISSN - 1618-1247
DOI - 10.1007/s10266-019-00477-9
Subject(s) - materials science , shore durometer , dynamic mechanical analysis , composite material , viscoelasticity , dynamic modulus , differential scanning calorimetry , silicone , glass transition , dissipation factor , rheometry , dielectric , thermodynamics , polymer , physics , optoelectronics
Soft denture liners and tissue conditioners are widely used for the denture patients to cushion masticatory force and condition abused tissues, respectively. This study assessed methods for the evaluation of the viscoelasticity and glass transition temperature (T g ) of the silicone permanent soft liner, acrylic permanent soft liner, and tissue conditioner. Three rheological parameters of storage modulus (E'), loss modulus (E''), and loss tangent ([Formula: see text]), T g , and hardness were determined using dynamic mechanical analysis (DMA), differential scanning calorimetry (DSC), and the Shore A0 hardness test. Five specimens were measured for each material. The time-temperature superposition principle was applied to produce master curves of E', E'', and [Formula: see text] for the tested materials at a reference temperature of 37 °C. The acrylic permanent soft liner and tissue conditioner exhibited viscoelastic behavior and sensitivity to frequency, especially at lower frequencies. The silicone permanent soft liner showed elastic behavior and was frequency-independent. T g for the acrylic permanent soft liner was higher than that for the tissue conditioner, which in turn was higher than that for the silicone permanent soft liner for both DMA and DSC. In DMA, a higher frequency led to higher T g values. A positive linear relationship was found between Shore A0 hardness and E' values, but not E'' and [Formula: see text] values. Shore hardness reflects elasticity, but not viscosity. The results of the present study can be used to improve methods for evaluating the viscoelasticity and T g of soft denture liners and tissue conditioners.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom