Subject(s) - ammonium hydroxide , chromatography , chemistry , lecithin , resolution (logic) , flame ionization detector , high performance liquid chromatography , chloroform , methanol , solvent , hydroxide , analytical chemistry (journal) , gas chromatography , organic chemistry , artificial intelligence , computer science
The three major soy phospholipids were determined by normal phase high performance liquid chromatography with flame ionization detection. A Beckman Ultrasphere silica column was utilized with a solvent gradient composed of chloroform and premixed methanol/ ammonium hydroxide. This chromatographic system produced excellent resolution of the three major phospholipids and triglyceride component as well as some of the minor constituents in soy oil lecithin. Ammonium hydroxide improved peak shape and resolution but caused the peaks for the phospholipids to appear as doublets. Quantitative analysis was accomplished by the external standard method.