z-logo
Premium
Umbilical venous volume flow and fetal behavioral states in the normally developing fetus
Author(s) -
Boito S. M. E.,
Ursem N. T. C.,
Struijk P. C.,
Stijnen T.,
Wladimiroff J. W.
Publication year - 2004
Publication title -
ultrasound in obstetrics and gynecology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.202
H-Index - 141
eISSN - 1469-0705
pISSN - 0960-7692
DOI - 10.1002/uog.956
Subject(s) - medicine , fetus , umbilical artery , anesthesia , heart rate , cardiology , anatomy , pregnancy , blood pressure , biology , genetics
Objective To determine the relationship between umbilical venous (UV) volume flow and fetal behavioral states 1F (quiet sleep) and 2F (active sleep) in normal pregnancies at 36–40 weeks of gestation. Methods Fetal behavioral states were established in 17 normal pregnancies by means of combined assessment of fetal heart rate patterns (FHRP), and fetal eye and body movements. UV vessel area (mm 2 ) as obtained by tracing the inner vessel area using Labview and Imaq Vision software and UV time‐averaged flow velocity (mm/s Doppler) were multiplied to calculate UV volume flow (mL/min) including flow/kg fetus. The pulsatility index (PI) in the umbilical artery was also determined. In each woman, all parameters were measured between three and five times in each behavioral state. Data are reported as mean ± 1 SD and analyzed by paired t‐test. Results No statistically significant behavioral‐state‐related changes were observed for UV time‐averaged velocity and UV volume flow, resulting in UV volume flow/kg fetus of 69.1 ± 14.9 mL/min*kg at 1F and 71.6 ± 12.1 mL/min*kg at 2F (not significant). A statistically significant increase ( P = 0.02) was established for UV cross‐sectional area (46.4 ± 8.6 mm 2 vs. 49.0 ± 10.1 mm 2 ) and for fetal heart rate (FHR) from 134.2 ± 10.3 bpm in 1F to 144.2 ± 7 bpm in 2F. Umbilical artery PI was not significantly different between the two behavioral states. Conclusions On the basis of high venous vessel wall compliance, the significant increase in UV cross‐sectional area during fetal behavioral state 2F may be determined by a rise in mean venous pressure. The significant rise in FHR may reflect increased fetal cardiac output during state 2F while the resistance at the hepato‐ductal pathway remains relatively constant with the purpose of meeting raised energy demands during the active sleep state. This is further supported by the observed trend towards an increase in UV volume flow. Copyright © 2004 ISUOG. Published by John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here