z-logo
Premium
Descriptive analysis of different phenotypes of cardiac remodeling in fetal growth restriction
Author(s) -
RodríguezLópez M.,
CruzLemini M.,
ValenzuelaAlcaraz B.,
GarciaOtero L.,
Sitges M.,
Bijnens B.,
Gratacós E.,
Crispi F.
Publication year - 2017
Publication title -
ultrasound in obstetrics and gynecology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.202
H-Index - 141
eISSN - 1469-0705
pISSN - 0960-7692
DOI - 10.1002/uog.17365
Subject(s) - medicine , interquartile range , phenotype , gestational age , cardiology , ventricle , hypertrophic cardiomyopathy , birth weight , fetus , fetal growth , pregnancy , biology , genetics , gene , biochemistry
ABSTRACT Objective To identify different cardiac phenotypes among cases of fetal growth restriction ( FGR ). Methods Echocardiography was performed in 126 cases with FGR (birth weight < 10 th centile) and 64 appropriate‐for‐gestational‐age ( AGA ) fetuses. Principal component and cluster analyses were performed to identify different cardiac phenotypes among FGR cases. Results Three different cardiac phenotypes were identified among the FGR group: globular in 54% of cases, elongated in 29% of cases and hypertrophic in 17% of cases. Those with a globular heart had the lowest median left‐ventricular sphericity index (controls, 1.78 (interquartile range ( IQR ), 1.62–1.97); FGR elongated, 1.92 ( IQR , 1.78–2.09); FGR globular, 1.44 ( IQR , 1.36–1.52); FGR hypertrophic, 1.65 ( IQR , 1.42–1.77); P = 0.001). FGR cases with an elongated left ventricle had nearly normal cardiac dimensions. FGR cases with a hypertrophic phenotype had the highest median left‐ventricular wall thickness (controls, 1.22 ( IQR , 1.10–1.67) mm/kg; FGR elongated, 1.52 ( IQR , 1.28–1.86) mm/kg; FGR globular, 1.65 ( IQR , 1.39–1.99) mm/kg; FGR hypertrophic, 3.68 ( IQR , 3.45–4.71) mm/kg; P = 0.001) and cardiac dimensions. Globular and elongated phenotypes showed a fetoplacental profile of late‐onset FGR , while the hypertrophic phenotype showed signs of early‐onset FGR . The hypertrophic group also had the poorest perinatal results, having the lowest birth‐weight centile, gestational age at delivery and Apgar score and the highest postnatal blood pressure and aorta intima–media thickness. Conclusions FGR induces at least three different cardiac phenotypes, with early‐onset FGR cases being associated with a hypertrophic response and worse perinatal outcomes. This cardiac phenotypic classification may improve identification of FGR cases with the highest perinatal and long‐term cardiovascular risks. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here