z-logo
Premium
Non‐invasive high‐intensity focused ultrasound treatment of the placenta: a preliminary in‐vivo study using a simian model
Author(s) -
Caloone J.,
Huissoud C.,
Kocot A.,
Vincenot J.,
Dehay C.,
Giroud P.,
Misery P.,
Allias F.,
Rudigoz R. C.,
Melodelima D.
Publication year - 2017
Publication title -
ultrasound in obstetrics and gynecology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.202
H-Index - 141
eISSN - 1469-0705
pISSN - 0960-7692
DOI - 10.1002/uog.17350
Subject(s) - medicine , ultrasound , placenta , high intensity focused ultrasound , fetus , abdominal cavity , radiology , nuclear medicine , pregnancy , surgery , biology , genetics
Objective To demonstrate the feasibility and efficacy of high‐intensity focused ultrasound (HIFU) for the non‐invasive creation of placental lesions in a simian model. Methods Eight pregnant monkeys were exposed to HIFU treatment after anesthesia, using a toroidal HIFU 2.5‐MHz transducer with an integrated ultrasound imaging probe. Lesions on the placental tissue were created non‐invasively by placing the HIFU probe on the skin surface. Fetal and maternal parameters, such as maternal heart rate, fetal heart rate and subcutaneous and intra‐amniotic fluid temperature, were recorded during HIFU exposure. Cesarean section was performed immediately after the procedure to extract the placenta and examine the fetus and the maternal abdominal cavity. Placental HIFU lesions were assessed by ultrasound, gross pathology and histology. Results The mean gestational age of the monkeys was 72 ± 4 days. In total, 13 HIFU procedures were performed. The acoustic power and exposure time were increased progressively. This gradual increase in total energy delivered was used to determine a set of parameters to create reproducible lesions in the placenta without complications. Five placental lesions were observed with average diameters of 6.4 ± 0.5 mm and 7.8 ± 0.7 mm and an average depth of 3.8 ± 1.5 mm. Ultrasound examination of the placentae revealed hyperechoic regions that correlated well with macroscopic analysis of the HIFU lesions. Necrosis of placental tissue exposed to HIFU was confirmed with macroscopic and microscopic analysis. There was no significant variation in maternal and fetal parameters during HIFU exposure. Conclusions This study demonstrates the feasibility of HIFU applied non‐invasively to the placental unit in an in‐vivo pregnant monkey model. The technique is safe in the immediate short term and is potentially translatable to human pregnancy. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here