Intra‐ and interobserver reproducibility of assessment of Doppler ultrasound findings in adnexal masses
Author(s) -
Zani L.,
Savelli L.,
Jokubkiene L.,
Di Legge A.,
Condous G.,
Testa A. C.,
Sladkevicius P.,
Valentin L.
Publication year - 2013
Publication title -
ultrasound in obstetrics and gynecology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.202
H-Index - 141
eISSN - 1469-0705
pISSN - 0960-7692
DOI - 10.1002/uog.12324
Subject(s) - medicine , intraclass correlation , kappa , reproducibility , cohen's kappa , adnexal mass , repeatability , ultrasound , nuclear medicine , limits of agreement , color doppler , radiology , adnexal diseases , ultrasonography , statistics , laparoscopy , mathematics , geometry
Objectives To estimate intra‐ and interobserver reproducibility and reliability of assessment of the color content in adnexal masses at color/power Doppler ultrasound examination for observers with different levels of experience, and to determine if they change after a consensus meeting . Methods Digital clips with color/power Doppler information on 103 adnexal masses were evaluated independently four times, twice before and twice after a consensus meeting, by four experienced and three less experienced ultrasound examiners. The color content of the adnexal mass was estimated using the International Ovarian Tumor Analysis color score and a 100‐mm visual analog scale ( VAS score). Intraobserver repeatability was estimated for each observer. Interobserver agreement was estimated for the four most experienced observers (six pairs), for the three less experienced observers (three pairs), and for four other pairs of observers, each pair consisting of one of the experienced and one of the less‐experienced observers . Results Intra‐ and interobserver agreement for the color score was moderate to very good, percentage agreement ranging from 48 to 82.5% (kappa, 0.52–0.82) before and from 59 to 90% (kappa, 0.60–0.88) after the consensus meeting. For seven of 13 pairs of observers, interobserver agreement improved after the consensus meeting. Intraobserver intraclass correlation coefficient ( ICC ) values for the VAS score ranged from 0.80 to 0.92 before and from 0.75 to 0.94 after the consensus meeting, but limits of agreement were wide (± 20–35 mm). For six of the seven observers the ICC values were higher after the consensus meeting than before. Interobserver ICC values for the VAS score ranged from 0.77 to 0.88 before and from 0.77 to 0.91 after the consensus meeting, but limits of agreement were wide (± 30–40 mm). For 10 of 13 pairs of observers the ICC values improved after the consensus meeting . Conclusions Intra‐ and interobserver agreement for the color score was good, especially after the consensus meeting, but there is room for improvement. VAS score results varied substantially within and between observers both before and after the consensus meeting. General consensus needs to be reached about how to interpret color/power Doppler ultrasound findings in adnexal masses. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd .