z-logo
Premium
Sensing layer combination of vertically aligned ZnO nanorods and graphene oxide for ultrahigh sensitivity IDE capacitive humidity sensor
Author(s) -
Pongampai Satana,
Pengpad Puttapon,
Meananeatra Rattanawan,
Chaisriratanakul Woraphan,
Poyai Amporn,
Horprathum Mati,
Chananawathorn Chanunthorn,
Titiroongruang Wisut,
Muanghlua Rangson
Publication year - 2020
Publication title -
ieej transactions on electrical and electronic engineering
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.254
H-Index - 30
eISSN - 1931-4981
pISSN - 1931-4973
DOI - 10.1002/tee.23140
Subject(s) - nanorod , wurtzite crystal structure , materials science , x ray photoelectron spectroscopy , scanning electron microscope , graphene , raman spectroscopy , oxide , optoelectronics , transmission electron microscopy , analytical chemistry (journal) , nanotechnology , chemical engineering , composite material , optics , chemistry , physics , chromatography , zinc , engineering , metallurgy
An interdigitated electrode (IDE) capacitive humidity sensor fabricated on a silicon substrate was used to investigate sensing materials, which proved to be an ultrahigh‐sensitivity humidity sensor. A sensing layer combination (SLC) between vertically aligned ZnO nanorods and optimal graphene oxide (GO) was prepared on the device and was tested as a humidity sensor. X‐ray diffractometry (XRD) exhibited crystallized wurtzite structure of ZnO nanorods and transmission electron microscope (TEM) shown perfectly indexed hexagonal wurtzite ZnO structure dots position correspondence. A scanning electron microscope (SEM) was used to analyze ZnO nanorods/GO morphologies. Furthermore, Raman spectroscopy and X‐ray photoelectron spectroscopy (XPS) clearly exhibited GO presence and hydrophilic functional groups (carboxyl, epoxy, and hydroxyl), respectively. The SLC prominently demonstrated ultrahigh sensitivity (up to 196.95% or 1.97 times from commercial sensor; HS1101, Humirel) and linear responses behavior with 0.96 for coefficient of determination. The device sensitivity obviously improved as steps of 40, 50, 60, 70, 80, and 90% RH at values of 1.09, 1.41, 1.51, 1.65, 1.80, and 1.91 times, respectively. The device also exhibited fast response (25 s) and short recovery times (17 s). Its hysteresis (6.58%) manifestly improved to 1.84 times. Moreover, repeatability and long‐term ability of the device demonstrated high accuracy (range ±0.37pF) and durability. © 2020 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom