Premium
Precision and accuracy of robot‐assisted technology with simplified express femoral workflow in measuring leg length and offset in total hip arthroplasty
Author(s) -
Cozzi Lepri Andrea,
Villano Marco,
Innocenti Matteo,
Porciatti Tommaso,
Matassi Fabrizio,
Civinini Roberto
Publication year - 2020
Publication title -
the international journal of medical robotics and computer assisted surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.556
H-Index - 53
eISSN - 1478-596X
pISSN - 1478-5951
DOI - 10.1002/rcs.2141
Subject(s) - total hip arthroplasty , workflow , medicine , radiography , offset (computer science) , mean difference , limits of agreement , arthroplasty , robotic surgery , robot , nuclear medicine , computer science , biomedical engineering , orthodontics , surgery , artificial intelligence , confidence interval , database , programming language
Abstract Background Semi‐active robot‐assisted total hip arthroplasty (THA) has two options to measure the leg length discrepancy (LLD) and combined offset (CO), the ‘enhanced’ femoral workflow and the so‐called ‘express’ simplified workflow. The purpose of this study was to determine the precision and accuracy of intraoperative LLD and CO measurement with express workflow robotic THA. Methods Between February 2018 and December 2019, 30 patients underwent an express workflow robot‐assisted primary THA for intraoperative LLD and CO measurements. Postoperative radiographs were used for LLD and CO measurement. In order to examine the accuracy of the robotic system assessment, the absolute difference between the robotic assessments and radiographic evaluations was calculated. Results Intraoperative robotic measurements reported a mean error of 0.2–0.6 mm for each registration, with no significant difference between them ( p = 0.311). The average absolute discrepancies between the robotic and radiographic assessments in the LLD and CO measurements were 1.3 ± 1.5 mm ( p = 0.17) and 1.1 ± 0.9 mm ( p = 0.11), respectively, while the Pearson's correlation coefficients were 0.69 and 0.71. Conclusions An external marker without a femoral array inserted into a screw positioned in the greater trochanter would be an easier and faster method to measure LLD and CO. Our study showed that the measured values of LLD and CO obtained by intraoperative express workflow robot‐assisted THA system were precise and accurate.