Isotope ratio infrared spectroscopy analysis of water samples without memory effects
Author(s) -
Graaf Stefan,
Vonhof Hubert B.,
Levy Elan J.,
Markowska Monika,
Haug Gerald H.
Publication year - 2021
Publication title -
rapid communications in mass spectrometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.528
H-Index - 136
eISSN - 1097-0231
pISSN - 0951-4198
DOI - 10.1002/rcm.9055
Subject(s) - chemistry , analytical chemistry (journal) , isotope , spectroscopy , water vapor , isotope ratio mass spectrometry , sample (material) , isotope analysis , infrared spectroscopy , stable isotope ratio , oxygen 18 , δ18o , isotopes of oxygen , chromatography , mass spectrometry , nuclear chemistry , ecology , physics , organic chemistry , quantum mechanics , biology
Rationale Since their introduction more than a decade ago, isotope ratio infrared spectroscopy (IRIS) systems have rapidly become the standard for oxygen ( δ 18 O) and hydrogen ( δ 2 H) isotope analysis of water samples. An important disadvantage of IRIS systems is the well‐documented sample‐to‐sample memory effect, which requires each sample to be analyzed multiple times before the desired accuracy is reached, lengthening analysis times and driving up the costs of analyses. Methods We present an adapted set‐up and calculation protocol for fully automated analysis of water samples using a Picarro L2140‐i cavity ring‐down spectroscopy instrument. The adaptation removes memory effects by use of a continuously moisturized nitrogen carrier gas. Water samples of 0.5 μL are measured on top of the water vapor background, after which isotope ratios are calculated by subtraction of the background from the sample peaks. Results With this new technique, single injections of water samples have internal precisions (1 σ ) below 0.05‰ for δ 18 O values and 0.1‰ for δ 2 H values, regardless of the isotope ratio of the previous sample. Precision is worse, however, when the isotope difference between the sample and background water is too large (i.e., exceeding approximately 9‰ for δ 18 O values and 70‰ for δ 2 H values). Isotope ratios show negligible drift across the four weeks within which the experiments were performed. The single‐injection 1 σ precision for 17 O excess (Δ′ 17 O) determined with this method is 60 per meg. Conclusions Our experiments demonstrate that by removing sample‐to‐sample memory effects with a moisturized carrier gas, the time for measurement of δ 18 O and δ 2 H values using an IRIS system can be reduced markedly without compromising the analytical precision and accuracy. Thorough replication is needed to achieve sufficiently low uncertainties for Δ′ 17 O.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here