Effects of HCl pretreatment, drying, and storage on the stable isotope ratios of soil and sediment samples
Author(s) -
Kim MinSeob,
Lee WonSeok,
Suresh Kumar K.,
Shin KyungHoon,
Robarge Wayne,
Kim Minseok,
Lee Sang Ryong
Publication year - 2016
Publication title -
rapid communications in mass spectrometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.528
H-Index - 136
eISSN - 1097-0231
pISSN - 0951-4198
DOI - 10.1002/rcm.7600
Subject(s) - chemistry , isotope , isotope analysis , stable isotope ratio , sediment , isotope ratio mass spectrometry , carbonate , environmental chemistry , mass spectrometry , analytical chemistry (journal) , chromatography , geology , paleontology , oceanography , physics , organic chemistry , quantum mechanics
Rationale Stable isotope (δ 13 C, δ 15 N, δ 34 S values) analysis has become increasingly important for tracing contaminant sources in environments. Pretreatment of environmental samples allows accurate analysis of stable isotope ratios. The pretreatment of a sample and its subsequent preservation could either contaminate or create experimental artifacts affecting the validity of the resulting C/N ratios and the elemental isotopic contents of a sample. Methods The effects of acid pretreatment (0.1, 0.5, 1, 2, 5, 13 M HCl) and exposure period (2, 6, 12, 24, and 48 h) on the stable isotopic ratios of marine sediment (MS), river sediment (RS) and terrestrial soil (TS) samples were evaluated. The effects of storage temperatures (–80, –20 and 2°C), storage duration (1 week, 1 to 12 months) and washing steps (1, 2, 3, 5, 7 or 12 times) on the stable isotopic ratios were also considered. The %C, %N and %S, as well as the δ 13 C, δ 15 N, and δ 34 S values, of each sample were measured using continuous flow Elemental Analyzer/Isotope Ratio Mass Spectrometry (EA/IRMS). Results The HCl treatment was applicable for δ 13 C analysis. However, the acid concentration and duration of exposure that brought about total removal of carbonate for the three sample types varied; e.g. the TS sample required stronger acid and a shorter exposure time. Storage time also had an effect: the δ 13 C values were lower and the δ 15 N and δ 34 S values higher after storage for 300 days. Conclusions HCl pretreatment effectively eliminates carbonates and thereby helps δ 13 C analysis of the organic fraction. HCl pretreatment is not recommended for δ 15 N and δ 34 S analysis. Freeze‐drying of samples is recommended rather than oven drying. A temperature‐dependent change in the isotopic ratios of long‐term stored samples was observed during this study; therefore, relatively short‐term storage (–80°C) of freeze‐dried samples is preferable. Copyright © 2016 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here