Improved performance of multiplexed targeted tandem mass spectrometry scans using customized Q Orbitrap data acquisition
Author(s) -
Kaufmann Anton,
Walker Stephan
Publication year - 2016
Publication title -
rapid communications in mass spectrometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.528
H-Index - 136
eISSN - 1097-0231
pISSN - 0951-4198
DOI - 10.1002/rcm.7532
Subject(s) - orbitrap , chemistry , multiplexing , mass spectrometry , tandem mass spectrometry , ion trap , ion , tandem mass tag , quantitative proteomics , analytical chemistry (journal) , chromatography , computer science , proteomics , telecommunications , biochemistry , organic chemistry , gene
Rationale The Q Orbitrap permits multiplexed targeted selected ion monitoring (SIM) or tandem mass spectrometry (MS/MS) scans. Such scans provide a significantly higher sensitivity than conventional full scan acquisition. However, due to the multiplexing, a monitored product ion extracted from a MS/MS scan can no longer be linked to the precursor ion from which it was derived. Furthermore, due to the automatic gain control, quantification based on targeted product ions acquired in the multiplexed MS/MS mode can become questionable. Methods The application programming interface (API) of the Q Exactive has been used to program a multiplexed targeted MS/MS mode that permits the establishment of a link (based on digital coding) between the product ion and the responsible precursor ion. Furthermore, switching off the automatic gain control feature and the definition of appropriate C‐trap settings were tested to improve the quantification performance. Results The use of dedicated decoding scans permitted the clear assignment of all monitored product ions to the responsible precursor ion. Furthermore, the customized multiplexed targeted scan used for quantification showed good sensitivity and linearity for a maximum number of eight co‐eluting analytes. Conclusions Multiplexed targeted MS/MS scans can be optimized to provide better selectivity (correct linking of an observed product ion to the responsible precursor ion) as well as improved quantitative performance (enforcement of an identical ion injection time for all targeted precursor ions). These two improvements are relevant for quantitative residue analysis. Copyright © 2016 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here