Extension of the Q Orbitrap intrascan dynamic range by using a dedicated customized scan
Author(s) -
Kaufmann A.,
Walker S.
Publication year - 2016
Publication title -
rapid communications in mass spectrometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.528
H-Index - 136
eISSN - 1097-0231
pISSN - 0951-4198
DOI - 10.1002/rcm.7530
Subject(s) - chemistry , orbitrap , extension (predicate logic) , dynamic range , chromatography , programming language , mass spectrometry , computer science , computer vision
Rationale The intrascan dynamic range of modern Orbitrap instrumentation is specified to reach 1:5000, while the interscan dynamic range is significantly larger due to the utilization of the automatic gain control feature. There are some applications (e.g. residue analysis in complex matrices, metabolomics or structural elucidation) where a wider intrascan dynamic range is desirable. Methods The Application Programming Interface (API) of the Q Exactive Orbitrap mass spectrometer has been used to program a customized scan in order to cover a larger intrascan dynamic range. Different approaches were used, which were all based on the variation of the isolation time of low‐abundance versus high‐abundance mass range segments. The differently attenuated mass range segments isolated by the quadrupole were sequentially forwarded to the C‐trap. Finally, the accumulated mass segments were measured within the Orbitrap analyzer. Results The spectra obtained by the customized scans show an enlarged dynamic range. This has been demonstrated by monitoring the higher isotope mass peaks (first and second isotope) of a low intensity analyte. Furthermore, a practical application (veterinary drugs in bovine kidney) has been investigated with the proposed customized scan. Analytes eluting within the retention time region of very intense matrix peaks (e.g. peptides) showed improved detectability when utilizing the customized scan. Conclusions The extension of the intrascan dynamic range by a customized scan is helpful when analyzing residues which happen to elute together with a dominating matrix peak or within a high ion abundance region (e.g. dead volume). Furthermore, this feature helps in the process of determining the elemental composition of compounds by permitting the investigation of low‐abundance ions (e.g. belonging to the isotopic fine structure of the investigated compound). Copyright © 2016 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here