Liquid chromatography/tandem mass spectrometry for simultaneous determination of undeclared corticosteroids in cosmetic creams
Author(s) -
Golubović Jelena B.,
Otašević Biljana M.,
Protić Ana D.,
Stanković Aleksandra M.,
Zečević Mira L.
Publication year - 2015
Publication title -
rapid communications in mass spectrometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.528
H-Index - 136
eISSN - 1097-0231
pISSN - 0951-4198
DOI - 10.1002/rcm.7403
Subject(s) - chemistry , chromatography , fluocinolone acetonide , betamethasone , triamcinolone acetonide , methylprednisolone acetate , mass spectrometry , clobetasol propionate , selected reaction monitoring , corticosteroid , electrospray ionization , tandem mass spectrometry , dermatology , surgery , medicine
Rationale Undeclared corticosteroids in creams intended for frequent use might cause serious side‐effects, especially in children. In order to prevent this or find the cause, it was essential to develop a method for quick detection and quantification of low levels of corticosteroids. Methods Eleven corticosteroids were used in this study: prednisolone, methylprednisolone, prednisolone‐21‐acetate, fluocinolone acetonide, fluocinolone acetonide‐21‐acetate, hydrocortisone‐21‐acetate, dexamethasone, betamethasone, betamethasone dipropionate, clobetasol propionate and triamcinolone. Separation was achieved via liquid chromatography (LC), and mass spectrometric analysis was conducted by electrospray ionization triple‐quadrupole mass spectrometry (MS/MS) in the multiple reaction monitoring mode using corticosterone as internal standard. Results Good separation by using a gradient‐elution LC/MS/MS method with run time of 25 min enabled the use of a segmented detection method and consecutive decrease in detection limits. The proposed method has been validated in the linearity range of 10–1000 ng/mL with coefficients of determination higher than 0.990. The method has shown to have very low limits of quantification (0.75–3 ng/mL) with satisfactory precision and accuracy for each of the corticosteroids. Conclusions An LC/MS/MS method for the rapid and simultaneous determination of low levels of eleven topical corticosteroids in creams was developed, optimized and validated. The proposed method can be used for testing of different products indicated for the treatment of atopic dermatitis, including "natural products", and "herbal creams" with "miraculous effects". Copyright © 2015 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here