z-logo
Premium
Novel method for measurement of glutathione kinetics in neonates using liquid chromatography coupled to isotope ratio mass spectrometry
Author(s) -
Schierbeek Henk,
te Braake Frans,
Godin JeanPhilippe,
Fay LaurentBernard,
van Goudoever Johannes B.
Publication year - 2007
Publication title -
rapid communications in mass spectrometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.528
H-Index - 136
eISSN - 1097-0231
pISSN - 0951-4198
DOI - 10.1002/rcm.3148
Subject(s) - chemistry , chromatography , glutathione , repeatability , isotope ratio mass spectrometry , mass spectrometry , isotope , tracer , analytical chemistry (journal) , norvaline , biochemistry , amino acid , physics , leucine , quantum mechanics , nuclear physics , enzyme
A novel analytical method using liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) was developed for measuring the fractional synthesis rate (FSR) of glutathione (GSH) in neonates after infusion of [1‐ 13 C]‐glycine as a tracer. After transformation of GSH into GSSG, its dimeric form, the intra‐erythrocytic concentration and 13 C‐isotopic enrichment of GSH were determined using 200 µL of blood. The results showed that, using LC/IRMS, the concentration (range of µmol/mL) was reliably measured using norvaline as internal standard with precision better than 0.1 µmol/mL. In addition, the 13 C‐isotopic enrichment measured in the same run gave reliable values with excellent precision (with standard deviation (sd) lower than 0.3‰) and accuracy (measured between 0 and 2 Atom % Excess (APE)). The inter‐assay repeatability of δ 13 C of norvaline used as internal standard with in vivo samples was assessed at −26.07 ± 0.28‰ with coefficient of variance (CV) at 1.1%. The FSR calculated either with GSH or GSSG showed similar results with slightly higher values for GSSG (41.6 ± 4.7 and 46.5 ± 4.4, respectively). The slightly lower FSR of GSH is probably due to interfering compounds in the biological matrix. Successfully used in a clinical study, this rapid and reliable method opens up a variety of kinetic studies with relatively low administration of tracer infusates, reducing the total cost of the study design. The small volume of blood needed enables studies even in extremely small subjects, such as premature infants, as reported in this study. Copyright © 2007 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here