z-logo
Premium
Matrix‐assisted laser desorption/ionization mass spectrometric peptide mapping of high molecular weight glutenin subunits 1Bx7 and 1Dy10 in Cheyenne cultivar
Author(s) -
Cozzolino Rosaria,
Giorgi Sabrina Di,
Fisichella Salvatore,
Garozzo Domenico,
Lafiandra Domenico,
Palermo Angela
Publication year - 2001
Publication title -
rapid communications in mass spectrometry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.528
H-Index - 136
eISSN - 1097-0231
pISSN - 0951-4198
DOI - 10.1002/rcm.299
Subject(s) - chemistry , edman degradation , mass spectrometry , trypsin , chromatography , glutenin , peptide sequence , protein primary structure , protein subunit , matrix assisted laser desorption/ionization , protein mass spectrometry , complementary dna , sample preparation , tandem mass spectrometry , biochemistry , desorption , gene , enzyme , organic chemistry , adsorption
This study describes the verification of the cDNA‐deduced amino acid sequences of high molecular weight glutenin subunits 1Dy10 and 1Bx7 in Cheyenne cultivar by direct matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) analysis of their tryptic fragments omitting chromatographic pre‐separation. These polypeptides have a conserved structure consisting of a long central repetitive domain that prevents the application of conventional sequencing procedures such as Edman degradation. The published sequence of subunit 1Dy10 contains 7 Lys and 13 Arg residues; thus the production of 21 tryptic peptides is expected. The cDNA‐deduced sequence for 1Bx7 subunit includes 5 Lys and 15 Arg residues, but the presence of three Arg‐Pro bonds, which are normally not cleaved by trypsin, predicts only 19 tryptic peptides. Three different matrices (DHB, SA and HCCA) in combination with the most compatible sample preparation procedures were used in order to obtain the maximum 1Dy10 and 1Bx7 sequence coverage. MALDI analysis of the 1Dy10 tryptic digest resulted in the identification of all 21 expected peptides. In the case of 1Bx7 MALDI analysis resulted in the identification of 17 of the 19 expected peptides, giving a sequence coverage of 99.3%. These results were sufficient to rule out glycosylation of the 1Dy10 and 1Bx7 proteins and to assess the absence of any other post‐translational modification, to within the detection limits of the method. Copyright © 2001 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here