z-logo
Premium
A comparison of different bedside techniques to determine endotracheal tube position in a neonatal piglet model
Author(s) -
Schmölzer Georg M.,
Bhatia Risha,
Davis Peter G.,
Tingay David G.
Publication year - 2013
Publication title -
pediatric pulmonology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.866
H-Index - 106
eISSN - 1099-0496
pISSN - 8755-6863
DOI - 10.1002/ppul.22580
Subject(s) - tidal volume , medicine , ventilation (architecture) , endotracheal tube , heart rate , respiratory rate , physics , anesthesia , respiratory system , intubation , blood pressure , thermodynamics
Rationale Endotracheal tube (ETT) malposition is common and an increasing number of non‐invasive techniques to aid rapid identification of tube position are available. Electrical impedance tomography (EIT) is advocated as a tool to monitor ventilation. Objective This study aimed to compare EIT with five other non‐invasive techniques for identifying ETT position in a piglet model. Methodology Six saline lavage surfactant‐depleted piglets were studied. Periods of ventilation with ETT placed in the oesophagus or a main bronchus (MB) were compared with an appropriately placed mid‐tracheal ETT. Colorimetric end‐tidal CO 2 (Pedi‐Cap®), SpO 2 and heart rate, tidal volume ( ${\rm V}_{{\rm T}_{{\rm ao}} } $ ) using a hot‐wire anemometer at the airway opening, tidal volume using respiratory inductive plethysmography ( ${\rm V}_{{\rm T}_{{\rm RIP}} } $ ) and regional tidal ventilation within each hemithorax (EIT) were measured. Results Oesophageal ventilation : Pedi‐Cap® demonstrated absence of color change. ${\rm V}_{{\rm T}_{{\rm ao}} } $ , ${\rm V}_{{\rm T}_{{\rm RIP}} } $ , and EIT correctly demonstrated no tidal ventilation. SpO 2 decreased from mean (SD) 96 (2)% to 74 (12)% ( P  < 0.05; Bonferroni post‐test), without heart rate change. MB ventilation: SpO 2 , heart rate and Pedi‐Cap® were unchanged compared with mid‐tracheal position. ${\rm V}_{{\rm T}_{{\rm ao}} } $ and ${\rm V}_{{\rm T}_{{\rm RIP}} } $ decreased from a mean (SD) 10.8 (5.6) ml/kg and 14.6 (6.2) ml/kg to 5.5 (1.9) ml/kg and 6.4 (2.6) ml/kg (both P  < 0.05; Bonferroni post‐test). EIT identified the side of MB ventilation, with a mean (SD) 95 (3)% reduction in tidal volume in the unventilated lung. Conclusions EIT not only correctly identified oesophageal ventilation but also localized the side of MB ventilation. At present, no one technique is without limitations and clinicians should utilize a combination in addition to clinical judgement. Pediatr Pulmonol. 2013; 48:138–145. © 2012 Wiley Periodicals, Inc.

This content is not available in your region!

Continue researching here.