Comparison of MRI measurements and CFD simulations of hemodynamics in intracranial aneurysms using a 3D printed model ‐ A benchmark problem
Author(s) -
Giese Daniel,
Heinlein Alexander,
Klawonn Axel,
Knepper Jascha,
Sonnabend Kristina
Publication year - 2019
Publication title -
pamm
Language(s) - English
Resource type - Journals
ISSN - 1617-7061
DOI - 10.1002/pamm.201900398
Subject(s) - computational fluid dynamics , benchmark (surveying) , magnetic resonance imaging , blood flow , computer science , mechanics , physics , radiology , medicine , geology , geodesy
A benchmark for the comparison of MRI (Magnetic Resonance Imaging) measurements and CFD (Computational Fluid Dynamics) simulations for blood flow in intracranial aneurysms is presented. The benchmark setting is designed to allow for CFD simulations that are completely independent of the MRI measurements. This facilitates a fair comparison of both methods. Furthermore, results showing the good agreement of MRI and CFD are presented.