Combined diffusion weighting and CSF suppression in functional MRI
Author(s) -
Andersson Linda,
Bolling Max,
Wirestam Ronnie,
Holtås Stig,
Ståhlberg Freddy
Publication year - 2002
Publication title -
nmr in biomedicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.278
H-Index - 114
eISSN - 1099-1492
pISSN - 0952-3480
DOI - 10.1002/nbm.767
Subject(s) - nuclear magnetic resonance , pulse sequence , partial volume , pulse (music) , noise reduction , communication noise , pixel , noise (video) , chemistry , physics , biomedical engineering , nuclear medicine , optics , artificial intelligence , computer science , medicine , acoustics , image (mathematics) , linguistics , philosophy , detector
In this study, EPI pulse sequences with diffusion weighting for reduction of contributions from large vessels and inversion pulses in order to minimize the effects of CSF pulsations and CSF partial volume effects were developed for BOLD contrast investigations in functional MR imaging. One inversion recovery echo‐planar imaging (IR‐EPI) pulse sequence and one IR‐EPI with additional diffusion weighting (DW‐IR‐EPI) were developed and compared to a standard gradient‐echo EPI sequence in a cortical stimulation experiment in nine healthy volunteers. Stimulation of motor cortex was performed using a semi‐complex finger‐tapping paradigm in seven periods of alternating rest and stimulation. Comparison between the three pulse sequences was made by measuring the activated volume in each subject, as well as by calculating the relative signal increase during stimulation. Due to different baseline signal‐to‐noise levels in the images generated by the three pulse sequences, artificial noise was added so that the comparative investigation could be performed independently of the noise level. The activated volume was 128 ± 73 pixels (mean ± SD) using the standard EPI pulse sequence, 31 ± 12 pixels using IR‐EPI and 15 ± 13 pixels when DW‐IR‐EPI was employed. The relative signal increase was 5.7 ± 1.1% using standard EPI, 11.5 ± 3.1% using IR‐EPI and 9.9 ± 2.4% using DW‐IR‐EPI. The activated volume obtained with the addition of extra noise, i.e. at equal S/N, was 70 ± 50 pixels using the standard EPI, and when using IR‐EPI, the activated volume was 28 ± 13 pixels. At equal S/N, the signal increase was 7.3 ± 1.4% using standard EPI and 12.0 ± 3.6% using IR‐EPI. In BOLD contrast imaging, a combination of diffusion weighting and inversion recovery appeared to reduce false activation caused by CSF pulsation and blood flow in large vessels. Copyright © 2002 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here