z-logo
Premium
Feasibility of 31 P spectroscopic imaging at 7 T in lung carcinoma patients
Author(s) -
Houtum Quincy .Q..,
Mohamed Hoesein Firdaus .F.A.A..,
Verhoeff Joost .J.J.C..,
Rossum Peter .P.S.N..,
Lindert Anne .A.S.R..,
Velden Tijl .T.A..,
Kemp Wybe .W.J.M..,
Klomp Dennis .D.W.J..,
Arteaga de Castro Catalina .C.S..
Publication year - 2021
Publication title -
nmr in biomedicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.278
H-Index - 114
eISSN - 1099-1492
pISSN - 0952-3480
DOI - 10.1002/nbm.4204
Subject(s) - flip angle , nuclear medicine , electromagnetic coil , nuclear magnetic resonance , materials science , magnetic resonance imaging , optics , physics , medicine , radiology , quantum mechanics
Currently, it is difficult to predict effective therapy response to molecular therapies for the treatment of lung cancer based solely on anatomical images. 31 P MR spectroscopic imaging could provide as a non‐invasive method to monitor potential biomarkers for early therapy evaluation, a necessity to improve personalized care and reduce cost. However, surface coils limit the imaging volume in conventional 31 P MRSI. High‐energetic adiabatic RF pulses are required to achieve flip angle homogeneity but lead to high SAR. Birdcage coils permit use of conventional amplitude modulated pulses, even over large FOV, potentially decreasing overall SAR massively. Here, we investigate the feasibility of 3D 31 P MRSI at 7 T in lung carcinoma patients using an integrated 31 P birdcage body coil in combination with either a dual‐coil or a 16‐channel receiver. Simulations showed a maximum decrease in SNR per unit of time of 8% for flip angle deviations in short TR low flip‐angle excitation 3D CSI. The minimal SNR loss allowed for fast 3D CSI without time‐consuming calibration steps (>10:00 min.). 31 P spectra from four lung carcinoma patients were acquired within 29:00 minutes and with high SNR using both receivers. The latter allowed discrimination of individual phosphodiesters, inorganic phosphate, phosphocreatine and ATP. The receiver array allowed for an increased FOV compared to the dual‐coil receiver. 3D 31 P‐CSI were acquired successfully in four lung carcinoma patients using the integrated 31 P body coil at ultra‐high field. The increased spectral resolution at 7 T allowed differentiation of multiple 31 P metabolites related to phospholipid and energy metabolism. Simulations provide motivation to exclude 31 P B 1 calibrations, potentially decreasing total scan duration. Employing large receiver arrays improves the field of view allowing for full organ coverage. 31 P MRSI is feasible in lung carcinoma patients and has potential as a non‐invasive method for monitoring personalized therapy response in lung tumors .

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here