z-logo
Premium
Diffusion‐weighted MRI of the prostate without susceptibility artifacts: Undersampled multi‐shot turbo‐STEAM with rotated radial trajectories
Author(s) -
Merrem Andreas,
Hofer Sabine,
Seif Amir Hosseini Ali,
Voit Dirk,
Merboldt KlausDietmar,
Tan Zhengguo,
Frahm Jens
Publication year - 2019
Publication title -
nmr in biomedicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.278
H-Index - 114
eISSN - 1099-1492
pISSN - 0952-3480
DOI - 10.1002/nbm.4074
Subject(s) - diffusion mri , turbo , fast spin echo , single shot , computer science , nuclear magnetic resonance , diffusion , radiology , biomedical engineering , magnetic resonance imaging , physics , materials science , artificial intelligence , medicine , engineering , optics , automotive engineering , thermodynamics
The aim of this study was to develop and evaluate a clinically feasible approach to diffusion‐weighted (DW) MRI of the prostate without susceptibility‐induced artifacts. The proposed method relies on an undersampled multi‐shot DW turbo‐STEAM sequence with rotated radial trajectories and a multi‐step inverse reconstruction with denoised multi‐shot phase maps. The total acquisition time was below 6 min for a resolution of 1.4 × 1.4 × 3.5 mm 3 and six directions at b  = 600 s mm −2 . Studies of eight healthy subjects and two patients with prostate cancer were performed at 3 T employing an 18‐channel body‐array coil and elements of the spine coil. The method was compared with conventional DW echo‐planar imaging (EPI) of the prostate. The results confirm that DW STEAM MRI avoids geometric distortions and false image intensities, which were present for both single‐shot EPI (ssEPI) and readout‐segmented EPI, particularly near the intestinal wall of the prostate. Quantitative accuracy of the apparent diffusion coefficient (ADC) was validated with use of a numerical phantom providing ground truth. ADC values in the central prostate gland of healthy subjects were consistent with those measured using ssEPI and with literature data. Preliminary results for patients with prostate cancer revealed a correct anatomical localization of lesions with respect to T 2 ‐weighted MRI in both mean DW STEAM images and ADC maps. In summary, DW STEAM MRI of the prostate offers clinically relevant advantages for the diagnosis of prostate cancer compared with state‐of‐the‐art EPI‐based approaches. The method warrants extended clinical trials.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here