Hepatic arterial spin labelling MRI: an initial evaluation in mice
Author(s) -
Ramasawmy R.,
CampbellWashburn A. E.,
Wells J. A.,
Johnson S. P.,
Pedley R. B.,
WalkerSamuel S.,
Lythgoe M. F.
Publication year - 2015
Publication title -
nmr in biomedicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.278
H-Index - 114
eISSN - 1099-1492
pISSN - 0952-3480
DOI - 10.1002/nbm.3251
Subject(s) - repeatability , coefficient of variation , reproducibility , perfusion , nuclear medicine , medicine , magnetic resonance imaging , radiology , pathology , chemistry , chromatography
The development of strategies to combat hepatic disease and augment tissue regeneration has created a need for methods to assess regional liver function. Liver perfusion imaging has the potential to fulfil this need, across a range of hepatic diseases, alongside the assessment of therapeutic response. In this study, the feasibility of hepatic arterial spin labelling (HASL) was assessed for the first time in mice at 9.4 T, its variability and repeatability were evaluated, and it was applied to a model of colorectal liver metastasis. Data were acquired using flow‐sensitive alternating inversion recovery‐arterial spin labelling (FAIR‐ASL) with a Look–Locker readout, and analysed using retrospective respiratory gating and a T 1 ‐based quantification. This study shows that preclinical HASL is feasible and exhibits good repeatability and reproducibility. Mean estimated liver perfusion was 2.2 ± 0.8 mL/g/min (mean ± standard error, n  = 10), which agrees well with previous measurements using invasive approaches. Estimates of the variation gave a within‐session coefficient of variation (CV WS ) of 7%, a between‐session coefficient of variation (CV BS ) of 9% and a between‐animal coefficient of variation (CV A ) of 15%. The within‐session Bland–Altman repeatability coefficient (RC WS ) was 18% and the between‐session repeatability coefficient (RC BS ) was 29%. Finally, the HASL method was applied to a mouse model of liver metastasis, in which significantly lower mean perfusion (1.1 ± 0.5 mL/g/min, n  = 6) was measured within the tumours, as seen by fluorescence histology. These data indicate that precise and accurate liver perfusion estimates can be achieved using ASL techniques, and provide a platform for future studies investigating hepatic perfusion in mouse models of disease. Copyright © 2014 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here