z-logo
Premium
Evaluation of segmented 3D acquisition schemes for whole‐brain high‐resolution arterial spin labeling at 3 T
Author(s) -
Vidorreta Marta,
Balteau Evelyne,
Wang Ze,
De Vita Enrico,
Pastor María A.,
Thomas David L.,
Detre John A.,
FernándezSeara María A.
Publication year - 2014
Publication title -
nmr in biomedicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.278
H-Index - 114
eISSN - 1099-1492
pISSN - 0952-3480
DOI - 10.1002/nbm.3201
Subject(s) - physics , image resolution , voxel , nuclear medicine , nuclear magnetic resonance , image quality , multislice , perfusion , arterial spin labeling , perfusion scanning , biomedical engineering , computer science , artificial intelligence , optics , medicine , radiology , image (mathematics)
Recent technical developments have significantly increased the signal‐to‐noise ratio (SNR) of arterial spin labeled (ASL) perfusion MRI. Despite this, typical ASL acquisitions still employ large voxel sizes. The purpose of this work was to implement and evaluate two ASL sequences optimized for whole‐brain high‐resolution perfusion imaging, combining pseudo‐continuous ASL (pCASL), background suppression (BS) and 3D segmented readouts, with different in‐plane k ‐space trajectories. Identical labeling and BS pulses were implemented for both sequences. Two segmented 3D readout schemes with different in‐plane trajectories were compared: Cartesian (3D GRASE) and spiral (3D RARE Stack‐Of‐Spirals). High‐resolution perfusion images (2 × 2 × 4 mm 3 ) were acquired in 15 young healthy volunteers with the two ASL sequences at 3 T. The quality of the perfusion maps was evaluated in terms of SNR and gray‐to‐white matter contrast. Point‐spread‐function simulations were carried out to assess the impact of readout differences on the effective resolution. The combination of pCASL, in‐plane segmented 3D readouts and BS provided high‐SNR high‐resolution ASL perfusion images of the whole brain. Although both sequences produced excellent image quality, the 3D RARE Stack‐Of‐Spirals readout yielded higher temporal and spatial SNR than 3D GRASE (spatial SNR = 8.5 ± 2.8 and 3.7 ± 1.4; temporal SNR = 27.4 ± 12.5 and 15.6 ± 7.6, respectively) and decreased through‐plane blurring due to its inherent oversampling of the central k ‐space region, its reduced effective T E and shorter total readout time, at the expense of a slight increase in the effective in‐plane voxel size. Copyright © 2014 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here