z-logo
Premium
Hexamethyldisiloxane‐based nanoprobes for 1 H MRI oximetry
Author(s) -
Gulaka Praveen K.,
Rastogi Ujjawal,
McKay Madalyn A.,
Wang Xianghui,
Mason Ralph P.,
Kodibagkar Vikram D.
Publication year - 2011
Publication title -
nmr in biomedicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.278
H-Index - 114
eISSN - 1099-1492
pISSN - 0952-3480
DOI - 10.1002/nbm.1678
Subject(s) - hexamethyldisiloxane , chemistry , oxygen , in vivo , biocompatibility , pulmonary surfactant , oxygenation , calibration curve , analytical chemistry (journal) , chromatography , biomedical engineering , detection limit , anesthesia , biochemistry , medicine , physics , plasma , microbiology and biotechnology , organic chemistry , quantum mechanics , biology
Quantitative in vivo oximetry has been reported using 19 F MRI in conjunction with reporter molecules, such as perfluorocarbons, for tissue oxygenation ( p O 2 ). Recently, hexamethyldisiloxane (HMDSO) has been proposed as a promising alternative reporter molecule for 1 H MRI‐based measurement of p O 2 . To aid biocompatibility for potential systemic administration, we prepared various nanoemulsion formulations using a wide range of HMDSO volume fractions and HMDSO to surfactant ratios. Calibration curves ( R 1 versus p O 2 ) for all emulsion formulations were found to be linear and similar to neat HMDSO for low surfactant concentrations (< 10% v/v). A small temperature dependence in the calibration curves was observed, similar to previous reports on neat HMDSO, and was characterized to be approximately 1 Torr/ °C under hypoxic conditions. To demonstrate application in vivo , 100 µL of this nanoemulsion was administered to healthy rat thigh muscle (Fisher 344, n  = 6). Dynamic changes in mean thigh tissue p O 2 were measured using the PISTOL (proton imaging of siloxanes to map tissue oxygenation levels) technique in response to oxygen challenge. Changing the inhaled gas to oxygen for 30 min increased the mean p O 2 significantly ( p  < 0.001) from 39 ± 7 to 275 ± 27 Torr. When the breathing gas was switched back to air, the tissue p O 2 decreased to a mean value of 45 ± 6 Torr, not significantly different from baseline ( p  > 0.05), in 25 min. A first‐order exponential fit to this part of the p O 2 data (i.e. after oxygen challenge) yielded an oxygen consumption‐related kinetic parameter k  = 0.21 ± 0.04 min −1 . These results demonstrate the feasibility of using HMDSO nanoemulsions as nanoprobes of p O 2 and their utility to assess oxygen dynamics in vivo , further developing quantitative 1 H MRI oximetry. Copyright © 2011 John Wiley & Sons, Ltd.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here