Inter‐rater reliability determination for two tests of ulnar nerve conduction across the elbow
Author(s) -
Carroll Craig G.,
Landau Mark E.,
Rouhanian Minoo,
Campbell William W.
Publication year - 2017
Publication title -
muscle and nerve
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.025
H-Index - 145
eISSN - 1097-4598
pISSN - 0148-639X
DOI - 10.1002/mus.25390
Subject(s) - elbow , ulnar nerve , intraclass correlation , ulnar neuropathy , medicine , nerve conduction , wrist , orthodontics , anatomy , physical medicine and rehabilitation , surgery , clinical psychology , psychometrics
ABSTRACT Introduction The inter‐rater variability in determination of ulnar nerve conduction across the elbow compromises test accuracy. The extent of this variability is unknown. The objective of this study was to determine and compare inter‐rater reliability of variables derived from 2 different ulnar nerve conduction studies (NCSs) across the elbow. Methods Two investigators performed a standard ulnar NCS and a 6‐cm conduction time (Six‐Centimeter Conduction Time test, SCCT) on 60 extremities of asymptomatic subjects. In the standard test, below‐elbow (BE) and above‐elbow (AE) stimulation points were ≥ 10 cm apart, measured along a curved path, to calculate across‐elbow NCV. In SCCT, BE and AE were precisely 6 cm apart measured linearly to calculate CTE (conduction time elbow). Inter‐rater reliability was assessed by means of intraclass correlation coefficients (ICC). Results ICC for across‐elbow NCV and CTE were 0.726 and 0.801, respectively. Conclusions Reliability of CTE and across‐elbow NCV are similar. Shorter distances, if measured linearly, can be used to determine across‐elbow ulnar nerve conduction. Muscle Nerve 55: 664–668, 2017

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here