z-logo
Premium
Clinically compatible subject‐specific dynamic parallel transmit pulse design for homogeneous fat saturation and water‐excitation at 7T: Proof‐of‐concept for CEST MRI of the brain
Author(s) -
Lévy Simon,
Herrler Jürgen,
Liebert Andrzej,
Tkotz Katharina,
Fabian Moritz S.,
Eisen Christian,
Grodzki David,
Uder Michael,
Dörfler Arnd,
Zaiss Moritz,
Nagel Armin M.
Publication year - 2023
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.29412
Subject(s) - homogeneity (statistics) , mean squared error , excitation , nuclear magnetic resonance , root mean square , flip angle , homogeneous , chemistry , pulse sequence , physics , biological system , mathematics , analytical chemistry (journal) , computational physics , magnetic resonance imaging , statistics , statistical physics , medicine , biology , chromatography , quantum mechanics , radiology
Purpose To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water‐excitation (WE), in the context of CEST MRI. Methods “Universal” k T ‐points(for FS) and spiral non‐selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110°/0° for FS, 0°/5° for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. Results Witha 25%‐shorter pulse duration, pTx FS largely improved the FA homogeneity (root‐mean‐square‐error (RMSE) = 12.3° vs. 53.4° with circularly‐polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8° vs. 0.2° at the water frequency). Similarly, pTx WEshowed a trade‐off between FA homogeneity and spectral selectivity compared to pTx non‐selective pulses (RMSE = 0.9° and 1.1° at the fat and water frequencies, vs. 4.6° and 0.5°). In the brain, CEST metrics were reduced by up to 31.9% at −3.3 ppm with pTx FS, suggesting a mitigated lipid‐induced bias. Conclusion This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject‐specific B 0 heterogeneities online. This study highlights the lipid‐induced biases on the CEST z‐spectrum. The results are promising for body applications where B 0 heterogeneities and fat are more substantial.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here