Whole‐brain quantitative CEST MRI at 7T using parallel transmission methods and B 1 + correction
Author(s) -
Liebert Andrzej,
Tkotz Katharina,
Herrler Jürgen,
Linz Peter,
Mennecke Angelika,
German Alex,
Liebig Patrick,
Gumbrecht Rene,
Schmidt Manuel,
Doerfler Arnd,
Uder Michael,
Zaiss Moritz,
Nagel Armin M.
Publication year - 2021
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.28745
Subject(s) - repeatability , nuclear magnetic resonance , focus (optics) , pulse sequence , physics , coefficient of variation , nuclear medicine , magnetic resonance imaging , materials science , computer science , optics , mathematics , statistics , medicine , radiology
Purpose To enable whole‐brain quantitative CEST MRI at ultra‐high magnetic field strengths (B 0 ≥ 7T) within short acquisition times. Methods Multiple interleaved mode saturation (MIMOSA) was combined with fast online‐customized (FOCUS) parallel transmission (pTx) excitation pulses and B 1 + correction to achieve homogenous whole‐brain coverage. Examinations of 13 volunteers were performed on a 7T MRI system with 3 different types of pulse sequences: (1) saturation in circular polarized (CP) mode and CP mode readout, (2) MIMOSA and CP readout, and (3) MIMOSA and FOCUS readout. For comparison, the inverse magnetic transfer ratio metric for relayed nuclear Overhauser effect and amide proton transfer were calculated. To investigate the number of required acquisitions for a good B 1 + correction, 4 volunteers were measured with 6 different B 1 amplitudes. Finally, time point repeatability was investigated for 6 volunteers. Results MIMOSA FOCUS sequence using B 1 + correction, with both single and multiple points, reduced inhomogeneity of the CEST contrasts around the occipital lobe and cerebellum. Results indicate that the most stable inter‐subject coefficient of variation was achieved using the MIMOSA FOCUS sequence. Time point repeatability of MIMOSA FOCUS with single‐point B 1 + correction showed a maximum coefficient of variation below 8% for 3 measurements in a single volunteer. Conclusion A combination of MIMOSA FOCUS with a single‐point B 1 + correction can be used to achieve quantitative CEST measurements at ultra‐high magnetic field strengths. Compared to previous B 1 + correction methods, acquisition time can be reduced as additional scans required for B 1 + correction can be omitted.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here