z-logo
Premium
Mapping of CSF transport using high spatiotemporal resolution dynamic contrast‐enhanced MRI in mice: Effect of anesthesia
Author(s) -
Stanton Evan Hunter,
Persson Niklas Daniel Åke,
Gomolka Ryszard Stefan,
Lilius Tuomas,
Sigurðsson Björn,
Lee Hedok,
Xavier Anna Lenice Ribeiro,
Benveniste Helene,
Nedergaard Maiken,
Mori Yuki
Publication year - 2021
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.28645
Subject(s) - isoflurane , glymphatic system , xylazine , cerebrospinal fluid , dynamic contrast enhanced mri , propofol , ketamine , magnetic resonance imaging , medicine , chemistry , anesthesia , pathology , radiology
Purpose Dynamic contrast‐enhanced MRI (DCE‐MRI) represents the only available approach for glymphatic cerebrospinal fluid (CSF) flow 3D mapping in the brain of living animals and humans. The purpose of this study was to develop a novel DCE‐MRI protocol for mapping of the glymphatic system transport with improved spatiotemporal resolution, and to validate the new protocol by comparing the transport in mice anesthetized with either isoflurane or ketamine/xylazine. Methods The contrast agent, gadobutrol, was administered into the CSF of the cisterna magna and its transport visualized continuously on a 9.4T preclinical scanner using 3D fast‐imaging with a steady‐state free‐precession sequence (3D‐FISP), which has a spatial resolution of 0.001 mm 3 and a temporal resolution of 30 s. The MR signals were measured dynamically for 60 min in multiple volumes of interest covering the entire CSF space and brain parenchyma. Results The results confirm earlier findings that glymphatic CSF influx is higher under ketamine/xylazine than with isoflurane anesthesia. This was extended to account for new details about the distinct CSF efflux pathways under the two anesthetic regimens. Dynamic contrast MR shows that CSF clearance occurs mainly along the vagus nerve near the jugular vein under isoflurane and via the olfactory bulb under ketamine/xylazine. Conclusion The improved spatial and temporal sampling rates afforded by 3D‐FISP shed new light on the pharmacological modulation of CSF efflux paths. The present observations may have the potential to set a new standard for future experimental DCE‐MRI studies of the glymphatic system.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here