z-logo
Premium
Time‐efficient measurement of subtle blood–brain barrier leakage using a T 1 mapping MRI protocol at 7 T
Author(s) -
Kerkhof Marieke,
Voorter Paulien H. M.,
Canjels Lisanne P. W.,
Jong Joost J. A.,
Oostenbrugge Robert J.,
Kroon Abraham A.,
Jansen Jacobus F. A.,
Backes Walter H.
Publication year - 2021
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.28629
Subject(s) - extravasation , white matter , leakage (economics) , blood sampling , nuclear medicine , perfusion , blood–brain barrier , contrast (vision) , medicine , biomedical engineering , computer science , magnetic resonance imaging , artificial intelligence , radiology , pathology , central nervous system , economics , macroeconomics , endocrinology
Purpose Blood–brain barrier (BBB) disruption is commonly measured with DCE‐MRI using continuous dynamic scanning. For precise measurement of subtle BBB leakage, a long acquisition time (>20 minutes) is required. As extravasation of the contrast agent is slow, discrete sampling at strategic time points might be beneficial, and gains scan time for additional sequences. Here, we aimed to explore the feasibility of a sparsely sampled MRI protocol at 7 T. Methods The scan protocol consisted of a precontrast quantitative T 1 measurement, using an MP2RAGE sequence, and after contrast agent injection, a fast‐sampling dynamic gradient‐echo perfusion scan and two postcontrast quantitative T 1 measurements were applied. Simulations were conducted to determine the optimal postcontrast sampling time points for measuring subtle BBB leakage. The graphical Patlak approach was used to quantify the leakage rate ( K i ) and blood plasma volume ( v p ) of normal‐appearing white and gray matter. Results The simulations showed that two postcontrast T 1 maps are sufficient to detect subtle leakage, and most sensitive when the last T 1 map is acquired late, approximately 30 minutes, after contrast agent administration. The in vivo measurements found K i and v p values in agreement with other studies, and significantly higher values in gray matter compared with white matter (both p = .04). Conclusion The sparsely sampled protocol was demonstrated to be sensitive to quantify subtle BBB leakage, despite using only three T 1 maps. Due to the time‐efficiency of this method, it will become more feasible to incorporate BBB leakage measurements in clinical research MRI protocols.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here