z-logo
Premium
Universal nonselective excitation and refocusing pulses with improved robustness to off‐resonance for Magnetic Resonance Imaging at 7 Tesla with parallel transmission
Author(s) -
Van Damme L.,
Mauconduit F.,
Chambrion T.,
Boulant N.,
Gras V.
Publication year - 2021
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.28441
Subject(s) - excitation , magnetic resonance imaging , spins , flip angle , nuclear magnetic resonance , waveform , physics , optics , computer science , telecommunications , medicine , quantum mechanics , radiology , radar , condensed matter physics
Purpose In MRI at ultra‐high field, the k T ‐point and spiral nonselective (SPINS) pulse design techniques can be advantageously combined with the parallel transmission (pTX) and universal pulse techniques to create uniform excitation in a calibration‐free manner. However, in these approaches, pulse duration is typically increased as compared to standard hard pulses, and excitation quality in regions exhibiting large resonance frequency offsets often suffer. This limitation is inherent to structure of k T ‐point or SPINS pulse, and likely can be mitigated using parameterization‐free pulse design approaches. Methods The Gradient Ascent Pulse Engineering (GRAPE) algorithm was used to design parameterization‐free RF and magnetic field gradient (MFG) waveforms for creating 8 ∘ excitation, up to 105 ∘ scalable refocusing and inversion, nonselectively across the brain. Simulations were performed to provide flip angle normalized root‐mean‐squares error (FA‐NRMSE) estimations for the 8 ∘ and the 180 ∘k T ‐point, SPINS, and GRAPE pulses. GRAPE pulses were tested experimentally with anatomical head scans at 7T. Results As compared to k T ‐points and SPINS, GRAPE provided substantial improvement of excitation, refocusing, and inversion quality at off‐resonance while at least preserving the same global FA‐NRMSE performance. As compared to k T ‐points, GRAPE allowed for a substantial reduction of the pulse duration for the 8 ∘ excitation and the 105 ∘ refocusing. Conclusions Parameterization‐free universal nonselective pTX‐pulses were successfully computed using GRAPE. Performance gains as compared to k T ‐points were validated numerically and experimentally for three imaging protocols. In its current implementation, the computational burden of GRAPE limits its use to applications where pulse computations are not subject to time constraints.

This content is not available in your region!

Continue researching here.