z-logo
Premium
Quantitative 3D dynamic contrast‐enhanced (DCE) MR imaging of carotid vessel wall by fast T1 mapping using Multitasking
Author(s) -
Wang Nan,
Christodoulou Anthony G.,
Xie Yibin,
Wang Zhenjia,
Deng Zixin,
Zhou Bill,
Lee Sangeun,
Fan Zhaoyang,
Chang Hyukjae,
Yu Wei,
Li Debiao
Publication year - 2019
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.27553
Subject(s) - reproducibility , imaging phantom , intraclass correlation , nuclear medicine , flip angle , biomedical engineering , image quality , repeatability , magnetic resonance imaging , mathematics , medicine , computer science , radiology , artificial intelligence , statistics , image (mathematics)
Purpose To develop a dynamic contrast‐enhanced (DCE) MRI method capable of high spatiotemporal resolution, 3D carotid coverage, and T1‐based quantification of contrast agent concentration for the assessment of carotid atherosclerosis using a newly developed Multitasking technique. Methods 5D imaging with 3 spatial dimensions, 1 T1 recovery dimension, and 1 DCE time dimension was performed using MR Multitasking based on low‐rank tensor modeling, which allows direct T1 quantification with high spatiotemporal resolution (0.7 mm isotropic and 595 ms, respectively). Saturation recovery preparations followed by 3D segmented fast low angle shot readouts were implemented with Gaussian‐density random 3D Cartesian sampling. A bulk motion removal scheme was developed to improve image quality. The proposed protocol was tested in phantom and human studies. In vivo scans were performed on 14 healthy subjects and 7 patients with carotid atherosclerosis. Kinetic parameters including area under the concentration versus time curve (AUC), v p , K trans , and v e were evaluated for each case. Results Phantom experiments showed that T1 measurements using the proposed protocol were in good agreement with reference value ( R 2 = 0.96 ). In vivo studies demonstrated that AUC, v p , and K trans in the patient group were significantly higher than in the control group (0.63 ± 0.13 versus 0.42 ± 0.12, P < 0.001; 0.14 ± 0.05 versus 0.11 ± 0.03, P = 0.034; and 0.13 ± 0.04 versus 0.08 ± 0.02, P < 0.001, respectively). Results from repeated subjects showed good interscan reproducibility (intraclass correlation coefficient: v p , 0.83; K trans , 0.87; v e , 0.92; AUC, 0.94). Conclusion Multitasking DCE is a promising approach for quantitatively assessing the vascularity properties of the carotid vessel wall.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here