Premium
Compressed sensing in quantitative determination of GAG concentration in cartilage by microscopic MRI
Author(s) -
Wang Nian,
Badar Farid,
Xia Yang
Publication year - 2018
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.26973
Subject(s) - undersampling , cartilage , magnetic resonance imaging , nuclear magnetic resonance , chemistry , compressed sensing , biomedical engineering , glycosaminoglycan , magnetic resonance elastography , anatomy , physics , computer science , artificial intelligence , elastography , radiology , medicine , biochemistry , acoustics , ultrasound
Purpose To evaluate the potentials of compressed sensing (CS) in MRI quantification of glycosaminoglycan (GAG) concentration in articular cartilage at microscopic resolution. Methods T 1 ‐weighted 2D experiments of cartilage were fully sampled in k‐space with five inversion times at 17.6 μm resolution. These fully sampled k‐space data were re‐processed, by undersampling at various 1D and 2D CS undersampling factors (UFs). The undersampled data were reconstructed individually into 2D images using nonlinear reconstruction, which were used to calculate 2D maps of T 1 and GAG concentration. The values of T 1 and GAG in cartilage were evaluated at different UFs (up to 16, which used 6.25% of the data). K‐space sampling pattern and zonal variations were also investigated. Results Using 2D variable density sampling pattern, the T 1 images at UFs up to eight preserved major visual information and produced negligible artifacts. The GAG concentration remained accurate for different sub‐tissue zones at various UFs. The variation of the mean GAG concentration through the whole tissue depth was 1.20%, compared to the fully sampled results. The maximum variation was 2.24% in the deep zone of cartilage. Using 1D variable density sampling pattern, the quantitative T 1 mapping and GAG concentration at UFs up to 4 showed negligible variations. Conclusion This study demonstrates that CS could be beneficial in microscopic MRI (µMRI) studies of cartilage by acquiring less data, without losing significant accuracy in the quantification of GAG concentration. Magn Reson Med 79:3163–3171, 2018. © 2017 International Society for Magnetic Resonance in Medicine.