Free‐breathing combined three‐dimensional phase sensitive late gadolinium enhancement and T 1 mapping for myocardial tissue characterization
Author(s) -
Weingärtner Sebastian,
Akçakaya Mehmet,
Roujol Sébastien,
Basha Tamer,
Tschabrunn Cory,
Berg Sophie,
Anter Elad,
Nezafat Reza
Publication year - 2015
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.25495
Subject(s) - imaging phantom , multislice , gadolinium , nuclear medicine , image resolution , flip angle , nuclear magnetic resonance , scanner , computer science , magnetic resonance imaging , biomedical engineering , medicine , artificial intelligence , physics , materials science , radiology , metallurgy
Purpose To develop a novel MR sequence for combined three‐dimensional (3D) phase‐sensitive (PS) late gadolinium enhancement (LGE) and T 1 mapping to allow for simultaneous assessment of focal and diffuse myocardial fibrosis. Methods In the proposed sequence, four 3D imaging volumes are acquired with different T 1 weightings using a combined saturation and inversion preparation, after administration of a gadolinium contrast agent. One image is acquired fully sampled with the inversion time selected to null the healthy myocardial signal (the LGE image). The other three images are three‐fold under‐sampled and reconstructed using compressed sensing. An acquisition scheme with two interleaved imaging cycles and joint navigator‐gating of those cycles ensures spatial registration of the imaging volumes. T 1 maps are generated using all four imaging volumes. The signal‐polarity in the LGE image is restored using supplementary information from the T 1 fit to generate PS‐LGE images. The accuracy of the proposed method was assessed with respect to a inversion‐recovery spin‐echo sequence. In vivo T 1 maps and LGE images were acquired with the proposed sequence and quantitatively compared with 2D multislice Modified Look‐Locker inversion recovery (MOLLI) T 1 maps. Exemplary images in a patient with focal scar were compared with conventional LGE imaging. Results The deviation of the proposed method and the spin‐echo reference was < 11 ms in phantom for T 1 times between 250 and 600 ms, regardless of the inversion time selected in the LGE image. There was no significant difference in the in vivo T 1 times of the proposed sequence and the 2D MOLLI technique (myocardium: 292 ± 75 ms versus 310 ± 49 ms, blood‐pools: 191 ± 75 ms versus 182.0 ± 33). The LGE images showed proper nulling of the healthy myocardium in all subjects and clear depiction of scar in the patient. Conclusion The proposed sequence enables simultaneous acquisition of 3D PS‐LGE images and spatially registered 3D T 1 maps in a single scan. Magn Reson Med 74:1032–1041, 2015. © 2014 Wiley Periodicals, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here