z-logo
Premium
Dynamic and inherent B 0 correction for DTI using stimulated echo spiral imaging
Author(s) -
Avram Alexandru V.,
Guidon Arnaud,
Truong TrongKha,
Liu Chunlei,
Song Allen W.
Publication year - 2014
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.24767
Subject(s) - diffusion mri , spiral (railway) , spin echo , computer science , diffusion , echo (communications protocol) , nuclear magnetic resonance , physics , signal (programming language) , anisotropy , image resolution , fractional anisotropy , anisotropic diffusion , temporal resolution , field (mathematics) , computer vision , artificial intelligence , magnetic resonance imaging , optics , mathematics , mathematical analysis , pure mathematics , medicine , computer network , radiology , programming language , thermodynamics
Purpose To present a novel technique for high‐resolution stimulated echo diffusion tensor imaging with self‐navigated interleaved spirals readout trajectories that can inherently and dynamically correct for image artifacts due to spatial and temporal variations in the static magnetic field ( B 0 ) resulting from eddy currents, tissue susceptibilities, subject/physiological motion, and hardware instabilities. Methods The Hahn spin echo formed by the first two 90° radiofrequency pulses is balanced to consecutively acquire two additional images with different echo times and generate an inherent field map, while the diffusion‐prepared stimulated echo signal remains unaffected. For every diffusion‐encoding direction, an intrinsically registered field map is estimated dynamically and used to effectively and inherently correct for off‐resonance artifacts in the reconstruction of the corresponding diffusion‐weighted image. Results After correction with the dynamically acquired field maps, local blurring artifacts are specifically removed from individual stimulated echo diffusion‐weighted images and the estimated diffusion tensors have significantly improved spatial accuracy and larger fractional anisotropy. Conclusion Combined with the self‐navigated interleaved spirals acquisition scheme, our new method provides an integrated high‐resolution short‐echo time diffusion tensor imaging solution with inherent and dynamic correction for both motion‐induced phase errors and off‐resonance effects. Magn Reson Med 71:1044–1053, 2014. © 2013 Wiley Periodicals, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here