z-logo
Premium
Broadband slab selection with B   1 + mitigation at 7T via parallel spectral‐spatial excitation
Author(s) -
Setsompop Kawin,
Alagappan Vijayanand,
Gagoski Borjan A.,
Potthast Andreas,
Hebrank Franz,
Fontius Ulrich,
Schmitt Franz,
Wald L.L.,
Adalsteinsson E.
Publication year - 2009
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.21834
Subject(s) - bandwidth (computing) , excitation , computer science , broadband , imaging phantom , optics , pulse duration , physics , acoustics , telecommunications , laser , quantum mechanics
Chemical shift imaging benefits from signal‐to‐noise ratio (SNR) and chemical shift dispersion increases at stronger main field such as 7 Tesla, but the associated shorter radiofrequency (RF) wavelengths encountered require B   1 +mitigation over both the spatial field of view (FOV) and a specified spectral bandwidth. The bandwidth constraint presents a challenge for previously proposed spatially tailored B   1 +mitigation methods, which are based on a type of echovolumnar trajectory referred to as “spokes” or “fast‐k z ”. Although such pulses, in conjunction with parallel excitation methodology, can efficiently mitigate large B   1 +inhomogeneities and achieve relatively short pulse durations with slice‐selective excitations, they exhibit a narrow‐band off‐resonance response and may not be suitable for applications that require B   1 +mitigation over a large spectral bandwidth. This work outlines a design method for a general parallel spectral‐spatial excitation that achieves a target‐error minimization simultaneously over a bandwidth of frequencies and a specified spatial‐domain. The technique is demonstrated for slab‐selective excitation with in‐plane B   1 +mitigation over a 600‐Hz bandwidth. The pulse design method is validated in a water phantom at 7T using an eight‐channel transmit array system. The results show significant increases in the pulse's spectral bandwidth, with no additional pulse duration penalty and only a minor tradeoff in spatial B   1 +mitigation compared to the standard spoke‐based parallel RF design. Magn Reson Med 61:493–500, 2009. © 2009 Wiley‐Liss, Inc.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom