z-logo
Premium
Correction of chemical‐shift artifacts in multislice F‐19 imaging with perfluorooctyl bromide
Author(s) -
Özdemirel B.,
Nalcioglu O.
Publication year - 1992
Publication title -
magnetic resonance in medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.696
H-Index - 225
eISSN - 1522-2594
pISSN - 0740-3194
DOI - 10.1002/mrm.1910230212
Subject(s) - multislice , bromide , artifact (error) , nuclear magnetic resonance , materials science , nuclear medicine , chemistry , physics , computer science , medicine , artificial intelligence , organic chemistry
Chemical‐shift artifact correction methods for multislice F‐19 imaging with perfluorooctyl bromide are described and results obtained with physical phantoms presented. Utilization of the two long‐T2 spectral peaks of PFOB in multislice imaging enhances the imaging efficiency considerably. Simultaneous imaging of the adjacent slices is achieved by appropriately adjusting the slice selection gradient amplitude, the bandwidth, and the slice position offset frequency of the selective RF pulses in relation to the frequency separation between the two peaks. © 1992 Academic Press, Inc.

This content is not available in your region!