z-logo
Premium
The role of the construction and sensitive volume of compact ionization chambers on the magnetic field‐dependent dose response
Author(s) -
Delfs Björn,
Blum Isabel,
Tekin Tuba,
Schönfeld AnnBritt,
Kranzer Rafael,
Poppinga Daniela,
Giesen Ulrich,
Langner Frank,
Kapsch RalfPeter,
Poppe Björn,
Looe Hui Khee
Publication year - 2021
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1002/mp.14994
Subject(s) - ionization chamber , microbeam , monte carlo method , magnetic field , physics , beam (structure) , ionization , fluence , perpendicular , electron , atomic physics , optics , nuclear physics , irradiation , ion , statistics , geometry , mathematics , quantum mechanics
Purpose The magnetic‐field correction factors k B , Qof compact air‐filled ionization chambers have been investigated experimentally and using Monte Carlo simulations up to 1.5 T. The role of the nonsensitive region within the air cavity and influence of the chamber construction on its dose response have been elucidated. Materials and Methods The PTW Semiflex 3D 31021, PinPoint 3D 31022, and Sun Nuclear Cooperation SNC125c chambers were studied. The k B , Qfactors were measured at the experimental facility of the German National Metrology Institute (PTB) up to 1.4 T using a 6 MV photon beam. The chambers were positioned with the chamber axis perpendicular to the beam axis (radial); and parallel to the beam axis (axial). In both cases, the magnetic field was directed perpendicular to both the beam axis and chamber axis. Additionally, the sensitive volumes of these chambers have been experimentally determined using a focused proton microbeam and finite element method. Beside the simulations of k B , Qfactors, detailed Monte Carlo technique has been applied to analyse the secondary electron fluence within the air cavity, that is, the number of secondary electrons and the average path length as a function of the magnetic field strength. Results A nonsensitive volume within the air cavity adjacent to the chamber stem for the PTW chambers has been identified from the microbeam measurements and FEM calculations. The dose response of the three investigated ionization chambers does not deviate by more than 4% from the field‐free case within the range of magnetic fields studied in this work for both the radial and axial orientations. The simulated k B , Qfor the fully guarded PTW chambers deviate by up to 6% if their sensitive volumes are not correctly considered during the simulations. After the implementation of the sensitive volume derived from the microbeam measurements, an agreement of better than 1% between the experimental and Monte Carlo k B , Qfactors for all three chambers can be achieved. Detailed analysis reveals that the stem of the PTW chambers could give rise to a shielding effect reducing the number of secondary electrons entering the air cavity in the presence of magnetic field. However, the magnetic field dependence of their path length within the air cavity is shown to be weaker than for the SNC125c chamber, where the length of the air cavity is larger than its diameter. For this chamber it is shown that the number of electrons and their path lengths in the cavity depend stronger on the magnetic field. Discussion and conclusion For clinical measurements up to 1.5 T, the required k B , Qcorrections of the three chambers could be kept within 3% in both the investigated chamber orientations. The results reiterate the importance of considering the sensitive volume of fully guarded chambers, even for the investigated compact chambers, in the Monte Carlo simulations of chamber response in magnetic field. The resulting magnetic field‐dependent dose response has been demonstrated to depend on the chamber construction, such as the ratio between length and the diameter of the air cavity as well as the design of the chamber stem.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here