Achievable dose reductions with gonadal shielding for children and adults during abdominal/pelvic radiographic examinations: A Monte Carlo simulation
Author(s) -
Somasundaram Elanchezhian,
Brady Samuel L.,
Strauss Keith J.
Publication year - 2020
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1002/mp.14495
Subject(s) - imaging phantom , radiography , medicine , gonad , nuclear medicine , electromagnetic shielding , reduction (mathematics) , monte carlo method , shields , radiology , anatomy , materials science , mathematics , statistics , geometry , composite material
Purpose Recently, medical professionals have reconsidered the practice of routine gonadal shielding for radiographic examinations. The objective of this study was to evaluate the gonadal dose reduction achievable with gonadal shields in the primary beam during abdominal/pelvic radiographic examinations under ideal and non‐ideal shielding placement. Methods CT scans of CIRS anthropomorphic phantoms were used to perform voxelized Monte Carlo simulations of the photon transport during abdominal/pelvic radiographic examinations with standard filtration and 0.1 mm Cu + 1 mm Al added filtration to estimate gonadal doses for an adult, 5 yr old, and newborn phantom with and without gonadal shields. The reduction in dose when the shields were not placed at the ideal locations was also evaluated. The ratio of the number of scattered‐to‐primary photons (SPR) across the anteroposterior (AP) dimension of the phantoms was also reported. Results The simulated dose reduction with ideal shielding placement for the testes and ovaries ranged from 80% to 90% and 55% to 70% respectively. For children, a misalignment of the shield to the gonad of 4 cm reduced the measured dose reduction to the gonads to <10%. For adults, this effect did not occur until the misalignment increased to ~6 cm. Effects of dose reduction with and without the gonadal shields properly placed were similar for standard filtration and added filtration. SPR at the level of the testes was consistently <1 for all phantoms. SPR for ovaries was ~1.5 for the adult and 5‐yr old, and ~1 for the newborn phantom. Conclusion Dose reduction with ideal alignment of the simulated gonadal shield to the gonads in this study was greater for the testes than the ovaries; both reductions were substantial. However, the dose reductions were greatly reduced (to <10%) for both sexes with misalignment of the gonads to the shields by 4 cm for children and 6 cm for adults.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here