z-logo
Premium
A sparse orthogonal collimator for small animal intensity‐modulated radiation therapy part I: Planning system development and commissioning
Author(s) -
Woods Kaley,
Nguyen Dan,
Neph Ryan,
Ruan Dan,
O'Connor Daniel,
Sheng Ke
Publication year - 2019
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1002/mp.13872
Subject(s) - multileaf collimator , collimator , aperture (computer memory) , intensity modulation , radiation treatment planning , dosimetry , computer science , medical physics , nuclear medicine , radiation therapy , optics , algorithm , physics , medicine , radiology , acoustics , phase modulation , phase noise
Purpose To achieve more translatable preclinical research results, small animal irradiation needs to more closely simulate human radiotherapy. Although the clinical gold standard is intensity‐modulated radiation therapy (IMRT), the direct translation of this method for small animals is impractical. In this study we describe the treatment planning system for a novel dose modulation device to address this challenge. Methods Using delineated target and avoidance structures, a rectangular aperture optimization (RAO) problem was formulated to penalize deviations from a desired dose distribution and limit the number of selected rectangular apertures. RAO was used to create IMRT plans with highly concave targets in the mouse brain, and the plan quality was compared to that using a hypothetical miniaturized multileaf collimator (MLC). RAO plans were also created for a realistic application of mouse whole liver irradiation and for a highly complex two‐dimensional (2D) dose distribution as a proof‐of‐principle. Beam commissioning data, including output and off‐axis factors and percent depth dose (PDD) curves, were acquired for our small animal irradiation system and incorporated into the treatment planning system. A plan post‐processing step was implemented for aperture size‐specific dose recalculation and aperture weighting reoptimization. Results The first RAO test case achieved highly conformal doses to concave targets in the brain, with substantially better dose gradient, conformity, and target dose homogeneity than the hypothetical miniaturized MLC plans. In the second test case, a highly conformal dose to the liver was achieved with significant sparing of the kidneys. RAO also successfully replicated a complex 2D dose distribution with three prescription dose levels. Energy spectra for field sizes 1 to 20 mm were calculated to match the measured PDD curves, with maximum and mean dose deviations of 4.47 ± 0.30% and 1.71 ± 0.18%. The final reoptimization of aperture weightings for the complex RAO test plan was able to reduce the maximum and mean dose deviations between the optimized and recalculated dose distributions from 10.3% to 6.6% and 4.0% to 2.8%, respectively. Conclusions Using the advanced optimization techniques, complex IMRT plans were achieved using a simple dose modulation device. Beam commissioning data were incorporated into the treatment planning process to more accurately predict the resulting dose distribution. This platform substantially reduces the gap in treatment plan quality between clinical and preclinical radiotherapy, potentially increasing the value and flexibility of small animal studies.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here