Premium
An anthropomorphic abdominal phantom for deformable image registration accuracy validation in adaptive radiation therapy
Author(s) -
Liao Yuliang,
Wang Linjing,
Xu Xiangdong,
Chen Haibin,
Chen Jiawei,
Zhang Guoqian,
Lei Huaiyu,
Wang Ruihao,
Zhang Shuxu,
Gu Xuejun,
Zhen Xin,
Zhou Linghong
Publication year - 2017
Publication title -
medical physics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.473
H-Index - 180
eISSN - 2473-4209
pISSN - 0094-2405
DOI - 10.1002/mp.12229
Subject(s) - imaging phantom , hounsfield scale , materials science , biomedical engineering , dosimetry , fiducial marker , nuclear medicine , computer science , artificial intelligence , computed tomography , medicine , radiology
Purpose To design and construct a three‐dimensional (3D) anthropomorphic abdominal phantom for geometric accuracy and dose summation accuracy evaluations of deformable image registration ( DIR ) algorithms for adaptive radiation therapy ( ART ). Method Organ molds, including liver, kidney, spleen, stomach, vertebra, and two metastasis tumors, were 3D printed using contours from an ovarian cancer patient. The organ molds were molded with deformable gels made of different mixtures of polyvinyl chloride ( PVC ) and the softener dioctyl terephthalate. Gels with different densities were obtained by a polynomial fitting curve that described the relation between the Hounsfield unit ( HU ) and PVC ‐softener blending ratio. The rigid vertebras were constructed by molding of white cement and cellulose pulp. The final abdominal phantom was assembled by arranging all the fabricated organs inside a hollow dummy according to their anatomies, and sealed by deformable gel with averaged HU of muscle and fat. Fiducial landmarks were embedded inside the phantom for spatial accuracy and dose accumulation accuracy studies. Two channels were excavated to facilitate ionization chamber insertion for dosimetric measurements. Phantom properties such as deformable gel elasticity and HU stability were studied. The dosimetric measurement accuracy in the phantom was performed, and the DIR accuracies of three DIR algorithms available in the open source DIR toolkit‐ DIRART were also validated. Results The constructed deformable gel showed elastic behavior and was stable in HU values over times, proving to be a practical material for the deformable phantom. The constructed abdominal phantom consisted of realistic anatomies in terms of both anatomical shapes and densities when compared with its reference patient. The dosimetric measurements showed a good agreement with the calculated doses from the treatment planning system. Fiducial‐based accuracy analysis conducted on the constructed phantom demonstrated the feasibility of applying the phantom for organ‐wise DIR accuracy assessment. Conclusions We have designed and constructed an anthropomorphic abdominal deformable phantom with satisfactory elastic property, realistic organ density, and anatomy. This physical phantom can be used for routine validations of DIR geometric accuracy and dose accumulation accuracy in ART .